Multielement determination in medicinal plants using electrothermal vaporization coupled to ICP OES

Electrothermal vaporization (ETV)-inductively coupled plasma optical emission spectrometry (ICP OES) is proposed for multielement determination in powdered medicinal plants. Simultaneous determination of As, Cd, Cr, Cu, Mn, Ni, Pb and Zn was performed in 10 herbs consumed in Brazil. Heating of the E...

Full description

Saved in:
Bibliographic Details
Published inAnalytical methods Vol. 9; no. 23; pp. 3497 - 354
Main Authors Santos, C. M. M, Nunes, M. A. G, Costa, A. B, Pozebon, D, Duarte, F. A, Dressler, V. L
Format Journal Article
LanguageEnglish
Published 21.06.2017
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Electrothermal vaporization (ETV)-inductively coupled plasma optical emission spectrometry (ICP OES) is proposed for multielement determination in powdered medicinal plants. Simultaneous determination of As, Cd, Cr, Cu, Mn, Ni, Pb and Zn was performed in 10 herbs consumed in Brazil. Heating of the ETV system and the influence of carrier gas flow rate, modifier gas (Freon R12, CCl 2 F 2 ) flow rate and sample mass were evaluated and adjusted to obtain the best signal/noise ratio. Temperatures of 300 °C and 1800 °C were used for pyrolysis and vaporization, respectively. Freon has a strong influence on the pyrolysis and vaporization temperatures and the sensitivity. Although the partial elimination of the sample matrix and Freon can act to minimize matrix effects, standard addition calibration was necessary for direct element determination in solid samples. The accuracy of ETV-ICP OES measurements was evaluated by analysing two certified reference materials (NIST 1515 - Apple Leaves and NIST 1574 - Peach Leaves), and the comparison of results obtained by solution nebulization ICP OES (NEB-ICP OES) for acid decomposed samples. The results were in good agreement ( t -test at the 95% confidence level) with certified values and those obtained by NEB-ICP OES. Precision was better than 20%, considering the standard deviation of five replicates, and limits of detection and quantification varied from 0.01 to 0.48 and 0.03 to 1.60 μg g −1 , respectively. The proposed method allows the simultaneous determination of As, Cd, Cr, Cu, Mn, Ni, Pb and Zn in medicinal plants in less than 5 min, including the sample preparation step. Electrothermal vaporization (ETV) associated with inductively coupled plasma optical emission spectrometry (ICP OES) for elemental determination in medicinal herbs was investigated.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1759-9660
1759-9679
DOI:10.1039/c7ay01021d