Evaluation of Intradermal and Subcutaneous Infusion Set Performance Under 24-Hour Basal and Bolus Conditions

Background: This study sought to assess the function and delivery reliability of intradermal (ID) infusion sets used with commercial insulin pumps. Method: Healthy subjects (n = 43) were randomized to either ID or subcutaneous (SC) arms, and received basal/bolus placebo delivery for 24 hours. Subjec...

Full description

Saved in:
Bibliographic Details
Published inJournal of diabetes science and technology Vol. 9; no. 6; pp. 1282 - 1291
Main Authors McVey, Elaine, Keith, Steven, Herr, Joshua K., Sutter, Diane, Pettis, Ronald J.
Format Journal Article
LanguageEnglish
Published Los Angeles, CA SAGE Publications 27.08.2015
Subjects
Online AccessGet full text
ISSN1932-2968
1932-3107
DOI10.1177/1932296815598327

Cover

Loading…
More Information
Summary:Background: This study sought to assess the function and delivery reliability of intradermal (ID) infusion sets used with commercial insulin pumps. Method: Healthy subjects (n = 43) were randomized to either ID or subcutaneous (SC) arms, and received basal/bolus placebo delivery for 24 hours. Subjects received 4 of 8 infusion set combinations (ID: microneedle design A or B, with 2 pump brands [Animas or MiniMed]; SC: Teflon Quickset or steel Rapid-D, Animas pump only, with or without overtaping) and were evaluated for pump occlusion alarms, fluid leakage, pain, and tissue tolerability. A novel algorithm was developed to determine flow consistency based on fluid pressure, and the duration and occurrence rate for periods of unalarmed but interrupted flow (“silent occlusions’”) were compared. Results: ID delivery was successfully maintained over the 24-hour infusion period. The number of silent occlusions was lower for ID microneedle cannula design B than A (P < .01) and lower for Rapid-D SC device compared to Quick-set (P = .03). There was no significant difference in the number of occlusion alarms between the ID and SC devices with the Animas pump. However, the pumps tested with ID devices had significantly different alarm rates (MiniMed 29.5%, Animas 0%, P < .001). Leakage and tissue tolerability were comparable across devices. Conclusion: The ID infusion set reliably delivered diluent for an extended 24-hour period in healthy subjects and was well tolerated. Silent occlusion flow interruptions could be detected in both ID and SC infusion sets using a proprietary algorithm. This algorithm is a promising method for quantitatively evaluating infusion set flow performance.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ObjectType-Undefined-3
ISSN:1932-2968
1932-3107
DOI:10.1177/1932296815598327