Does proximal porous coating in short-stem humeral arthroplasty reduce stress shielding?

Context Short-stem humeral designs in shoulder arthroplasty have been introduced recently. A retrospective cohort study was conducted to determine if newer proximal porous titanium coating in humeral short stems produced clinical and radiologic improvements. Method Short-stem humeral implants (Torni...

Full description

Saved in:
Bibliographic Details
Published inShoulder & elbow Vol. 11; no. 2_suppl; pp. 56 - 66
Main Authors Tan, Martin T, Read, John W, Bokor, Desmond J
Format Journal Article
LanguageEnglish
Published London, England SAGE Publications 01.07.2019
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Context Short-stem humeral designs in shoulder arthroplasty have been introduced recently. A retrospective cohort study was conducted to determine if newer proximal porous titanium coating in humeral short stems produced clinical and radiologic improvements. Method Short-stem humeral implants (Tornier Ascend, Wright Medical) were used in 46 anatomical total shoulder replacements from October 2012 to December 2015. Clinical and radiologic measures were analyzed at one- and two-year follow-up. Results Nineteen shoulders received earlier grit blasted stems (Ascend Monolithic), and 27 shoulders received the later stems with proximal titanium porous coating (Ascend Flex). At two-year follow-up, radiographic changes and stress shielding were similar. Medial cortical thinning were more frequently observed in Monolithic (18 of 19) compared to Flex stems (19 of 27) on the PA films, though this was not statistically significant (P = 0.061). Clinical outcome scores improved regardless of the stem type used and independent of the radiologic adaptations on plain films. One participant with the Ascend Flex developed glenoid component failure and rotator cuff tear and was subsequently revised. Discussion Clinical and radiological outcomes are similar in both short-stem designs. Proximal titanium porous coating may reduce medial calcar cortical thinning but it does not prevent it. Key message When compared to similarly designed uncoated grit-blasted stems, proximally porous coated humeral short stems produced similar clinical and radiological results. The proximal titanium porous coating may reduce medial cortical thinning.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1758-5732
1758-5740
DOI:10.1177/1758573218773533