Investigative studies on the effects of cadmium rabbits on high enriched uranium-fueled and low enriched uranium-fueled cores of Ghana Research Reactor-1 using MCNP5 code

•The operating parameters for both the HEU core and proposed LEU core were similar.•The length of the Cd in the capsules must be increased for its use in the LEU core.•Cd rabbits can emergently be used to shut down MNSRs. Miniature Neutron Source Reactors (MNSRs) are noted to be among highly safe re...

Full description

Saved in:
Bibliographic Details
Published inNuclear engineering and design Vol. 265; pp. 514 - 518
Main Authors Boffie, J., Akaho, E.H.K., Nyarko, B.J.B., Odoi, H.C., Tuffour-Achampong, K., Abrefah, R.G.
Format Journal Article
LanguageEnglish
Published Elsevier B.V 01.12.2013
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:•The operating parameters for both the HEU core and proposed LEU core were similar.•The length of the Cd in the capsules must be increased for its use in the LEU core.•Cd rabbits can emergently be used to shut down MNSRs. Miniature Neutron Source Reactors (MNSRs) are noted to be among highly safe research reactors. However, because of its use of one control rod for reactivity control and shutdown purposes, alternative methods of shutting it down are important. The Ghana MNSR uses four cadmium rabbits of approximate dimensions 6.5cm×5.0cm×0.1cm and mass of 9.48g each to emergently shut down the reactor. The Monte Carlo N-Particle code; version 5, (MCNP5) was used to design the high enriched uranium (HEU) and low enriched uranium (LEU) cores of the MNSR with four cadmium rabbits inserted in four inner irradiation sites of each core. The operating parameters and shutdown parameters for both cores with the central control rod (CCR) either fully withdrawn or fully inserted had similar results with the HEU core having slightly better results in terms of safety. However, the results show that the four inserted cadmium rabbits make the HEU core subcritical whiles in the LEU core, it still remains critical (keff=1.00005±0.00007). The length of the cadmium material in each cadmium rabbit must therefore be increased by at least 0.5cm in order to attain subcriticality (keff=0.99989±0.00006) and shutdown margin of 0.11mk when inserted in the LEU core.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0029-5493
1872-759X