Continuous respiratory monitoring for sleep apnea screening by ambulatory hemodynamic monitor

AIM:To validate the sleep-disordered breathing components of a portable electrocardiography and hemodynamic monitor to be used for sleep apnea screening.METHODS:Sleep-disordered breathing(SDB) is associated with cardiovascular disease.Patients with existing cardiovascular disease may have unrecogniz...

Full description

Saved in:
Bibliographic Details
Published inWorld journal of cardiology Vol. 4; no. 4; pp. 121 - 127
Main Author Dillier, Roger
Format Journal Article
LanguageEnglish
Published United States Baishideng Publishing Group Co., Limited 26.04.2012
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:AIM:To validate the sleep-disordered breathing components of a portable electrocardiography and hemodynamic monitor to be used for sleep apnea screening.METHODS:Sleep-disordered breathing(SDB) is associated with cardiovascular disease.Patients with existing cardiovascular disease may have unrecognized SDB or may develop SDB while under the care of a cardiologist.A screening device for SDB,easy to use and appealing to cardiologists,would assist in referral of appropriate patients for full polysomnography(PSG).A cardiac and respiratory monitor(CPAM) was attached to patients undergoing PSG and an apnea/hypopnea index(AHI) generated.The CPAM device produced respiration rate,snoring rate,individual apnea/hypopnea events and an SDB severity score(SDBSS).In addition to AHI,an expert over-reader annotated individual breaths,snores and SDB breathing events to which the automated algorithms were compared.RESULTS:The test set consisted of data from 85 patients(age:50.5 ± 12.4 years).Of these,57 had a positive PSG defined as AHI ≥ 5.0(mean:30.0 ± 29.8,negative group mean:1.5 ± 1.2).The sensitivity and specificity of the SDBSS compared to AHI was 57.9% and 89.3%,respectively.The correlation of snoring rate by CPAM compared to the expert overreader was r = 0.58(mean error:1.52 snores/min),while the automated respiration rate had a correlation of r = 0.90(mean error:0.70 breaths/min).CONCLUSION:This performance assessment shows that CPAM can be a useful portable monitor for screening and follow-up of subjects for SDB.
Bibliography:Roger Dillier,Mabelle Young,Susanne Erne,Michel Zuber,Paul Erne,Division of Cardiology,Luzerner Kantonsspital,6000 Lucerne 16,Switzerland Markus Baumann,Bernhard Schwizer,Division of Pneumology,Center of Sleep Disorders,Luzerner Kantonsspital,6000 Lucerne 16,Switzerland
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
Correspondence to: Paul Erne, MD, FESC, Professor, Head of Cardiology, Luzerner Kantonsspital, Luzern, 6000 Lucerne 16, Switzerland. paul.erne@luks.ch
Telephone: +41-41-2055208 Fax: +41-41-2052234
Author contributions: Dillier R and Young M registered the patients and collected the acoustic cardiography data; Baumann M and Schwizer B carried out the polysomnography studies; Erne S performed data entry and quality control; Zuber M and Erne P designed the study and were involved in the analysis and interpretation of the data; Dillier R and Zuber M wrote the manuscript.
ISSN:1949-8462
1949-8462
DOI:10.4330/wjc.v4.i4.121