Subconjunctival sustained release 5-fluorouracil for glaucoma filtration surgery

Aim: To determine the release characteristics of a 5-fluorouracil-loaded poly (lactic acid) disc (5-FU-PLA-DS) and the effect of sustained drug delivery on the success of glaucoma filtration surgery in rabbit eyes. Methods: A method of microspheres accumulated by excessive carriers was used in the p...

Full description

Saved in:
Bibliographic Details
Published inActa pharmacologica Sinica Vol. 29; no. 9; pp. 1021 - 1028
Main Authors Cui, Li-jun, Sun, Nai-xue, Li, Xing-hua, Huang, Jie, Yang, Jian-gang
Format Journal Article
LanguageEnglish
Published London Nature Publishing Group UK 01.09.2008
Nature Publishing Group
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Aim: To determine the release characteristics of a 5-fluorouracil-loaded poly (lactic acid) disc (5-FU-PLA-DS) and the effect of sustained drug delivery on the success of glaucoma filtration surgery in rabbit eyes. Methods: A method of microspheres accumulated by excessive carriers was used in the preparation of the 5-FU-PLA-DS. The disc was characterized for drug loading, entrapment efficiency, in vitro release, and external morphology. It was then implanted subconjunctivally into rabbit eyes with trabeculectomy. Intraocular pressure, ocular inflammatory reaction, filtration bleb appearance, and persistence were evaluated up to postoperative d 90. A quantitative analysis of 5-fluorouracil (5-FU) was performed in the aqueous humor. Ultrasound biomicroscopy was used to assess the appearance of the filtering fistula. Results: The 5-FU-PLA-DS was produced with the drug-loading of 3.07±0.08 mg (mean±SD). 5-FU was released for 91 d with suppressive concentrations. The decrease in intraocular pressure from baseline was significantly more marked in the 5-FU-PLA-DSimplanted eyes during postoperative d 3-90, and the persistence of bleb and filtration fistula was longer than the control eyes (P〈0.05). Corneal toxicity and hyperemia triggered by 5-FU was lower in the 5-FU-PLA-DS-implanted eyes than those exposed to 5-FU intraoperatively. The 5-FU concentration in the aqueous humor was insufficient for corneal endothelial damage. No evidence of toxic reaction was found in the conjunctival biopsy. Conclusion: 5-FU-PLA- DS displaying sustained intraocular release of 5-FU, reduced intraocular pressure, and prolonged bleb persistence, while significantly reducing 5-FU toxicity.
Bibliography:5-fluorouracil; polymer; microsphere; sustained release; glaucoma; intraocular pressure; rabbit
5-fluorouracil
polymer
intraocular pressure
sustained release
glaucoma
rabbit
microsphere
R96
31-1347/R
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:1671-4083
1745-7254
1745-7254
DOI:10.1111/j.1745-7254.2008.00833.x