Anterior Chamber Configuration Changes after Cataract Surgery in Eyes with Glaucoma

To evaluate changes in anterior chamber depth (ACD) and angle width induced by phacoemulsification and intraocular lens (IOL) implantation in eyes with glaucoma, using anterior segment optical coherence tomography (AS-OCT). Eleven eyes of 11 patients with angle-closure glaucoma (ACG) and 12 eyes of...

Full description

Saved in:
Bibliographic Details
Published inKorean journal of ophthalmology Vol. 26; no. 2; pp. 97 - 103
Main Authors Kim, Martha, Park, Ki Ho, Kim, Tae-Woo, Kim, Dong Myung
Format Journal Article
LanguageEnglish
Published Korea (South) The Korean Ophthalmological Society 01.04.2012
대한안과학회
Subjects
Online AccessGet full text
ISSN1011-8942
2092-9382
2092-9382
DOI10.3341/kjo.2012.26.2.97

Cover

More Information
Summary:To evaluate changes in anterior chamber depth (ACD) and angle width induced by phacoemulsification and intraocular lens (IOL) implantation in eyes with glaucoma, using anterior segment optical coherence tomography (AS-OCT). Eleven eyes of 11 patients with angle-closure glaucoma (ACG) and 12 eyes of 12 patients with open-angle glaucoma (OAG) underwent phacoemulsification and IOL implantation. Using AS-OCT, ACD and angle parameters were measured before and 2 days after surgery. Change in intraocular pressure (IOP) and number of ocular hypotensive drugs were evaluated. After surgery, central ACD and angle parameters increased significantly in eyes with glaucoma (p < 0.05). Prior to surgery, mean central ACD in the ACG group was approximately 1.0 mm smaller than that in the OAG group (p < 0.001). Post surgery, mean ACD of the ACG group was still significantly smaller than that of the OAG group. No significant differences were found in angle parameters between the ACG and OAG groups. In the ACG group, postoperative IOP at the final visit was significantly lower than preoperative IOP (p = 0.018) and there was no significant change in the number of ocular hypotensive medications used, although clinically, patients required fewer medications. In the OAG group, the IOP and number of ocular hypotensive drugs were almost unchanged after surgery. The ACD and angle width in eyes with glaucoma increased significantly after phacoemulsification and IOL implantation. Postoperative ACD significantly differed between the ACG and OAG groups, whereas angle parameters did not differ.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
G704-002170.2012.26.2.006
ISSN:1011-8942
2092-9382
2092-9382
DOI:10.3341/kjo.2012.26.2.97