Energy and exergy analysis of forced and natural convection indirect solar dryers: Estimation of exergy inflow, outflow, losses, exergy efficiencies and sustainability indicators from drying experiments

In this study, energy and exergy analysis (EEA) was performed during drying of okra (Abelmoschus esculentus) in an indirect solar dryer (ISD) under forced and natural convection and results were compared for better assessment of the performance of ISD and optimize the drying process by considering t...

Full description

Saved in:
Bibliographic Details
Published inJournal of cleaner production Vol. 282; p. 124421
Main Authors Mugi, Vishnuvardhan Reddy, Chandramohan, V.P.
Format Journal Article
LanguageEnglish
Published Elsevier Ltd 01.02.2021
Subjects
Online AccessGet full text
ISSN0959-6526
1879-1786
DOI10.1016/j.jclepro.2020.124421

Cover

More Information
Summary:In this study, energy and exergy analysis (EEA) was performed during drying of okra (Abelmoschus esculentus) in an indirect solar dryer (ISD) under forced and natural convection and results were compared for better assessment of the performance of ISD and optimize the drying process by considering the quantity of energy. A divergent duct integrated with central processing unit (CPU) fans was attached to solar air collector (SAC) in forced convection ISD and this fitting was removed during natural convection experiments. The average SAC and drying efficiencies were 74.98% and 24.95% under forced convection and the same were 61.49% and 20.13% under natural convection, respectively. The exergy inflow, outflow and losses were determined for the collector and drying chamber for both setups. The exergy outflow of SAC was in a range of 1.04–46.85 W and 1.13–50.94 W, in forced and natural convection mode, respectively. The exergy loss for the drying chamber varied from 0.062 to 21.99 W and 0.394–24.99 W, under forced and natural convection, respectively. The values of average exergy efficiencies for SAC and drying chamber in forced convection ISD were 2.03 and 59.32%, while in natural convection, these were 2.44 and 55.45%, respectively. In forced convection ISD, the improvement potential was in the range of 0.0095–10.51 W while the sustainability index and waste exergy ratio varied from 1.19 to 17.05 and 0.06 to 0.83, respectively. EEA analysis revealed that the performance of forced convection was better than the natural convection ISD. Uncertainty of all parameters was estimated and updated in all plots in terms of error bars. [Display omitted] •Forced and natural convection indirect type solar dryers (ISD) were developed.•The average drying efficiency was 24.95 and 20.13% in forced and natural convection.•Exergy inflow, outflow and losses were determined for collector and drying chamber.•The exergy efficiency of drying chamber was between 15.17 and 97.75% for both setups.•The average sustainability index was 5.1 and 3.69 in forced and natural convection.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0959-6526
1879-1786
DOI:10.1016/j.jclepro.2020.124421