Ex vivo vibro-acoustography characterization of osteoporosis in an experimental mice model

Osteoporosis is a highly prevalent multifactorial osteometabolic disease, classically diagnosed, , by dual energy X-ray absorptiometry (DXA). This study evaluated osteoporosis, , using vibro-acoustography (VA), an elastographic technique based on ultrasound radiation force. Three groups of mice femu...

Full description

Saved in:
Bibliographic Details
Published inQuantitative imaging in medicine and surgery Vol. 11; no. 2; pp. 586 - 596
Main Authors Agnollitto, Paulo Moraes, de Araújo Braz, Guilherme, Spirlandeli, Adriano Levi, de Paula, Francisco José Albuquerque, Carneiro, Antonio Adilton Oliveira, Nogueira-Barbosa, Marcello Henrique
Format Journal Article
LanguageEnglish
Published China AME Publishing Company 01.02.2021
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Osteoporosis is a highly prevalent multifactorial osteometabolic disease, classically diagnosed, , by dual energy X-ray absorptiometry (DXA). This study evaluated osteoporosis, , using vibro-acoustography (VA), an elastographic technique based on ultrasound radiation force. Three groups of mice femurs were used: (I) control group (CG), (II) osteoporosis group (OG) and (III) treated osteoporosis group (TOG), in which the animals received pamidronate, an antiresorptive drug. Evaluation was performed in an acoustic tank, using two high frequency focused beams produced by a confocal ultrasonic transducer. A hydrophone registered the low frequency acoustic response (AR) of bone samples. We used micro-computed tomography (microCT) as the reference standard and evaluated the correlation between VA and microCT parameters. The spectral analyses of the ARs with estimated area under the curve (AUC) values (mean; st. dev.) were, respectively, 1.29e and 9.32e for the CG, 3.25e and 2.16e for the OG, and 1.50e and 8.37e for the TOG. VA differentiated the experimental groups (P<0.01) and the results were reproducible [interclass correlation coefficient (ICC): 0.43 (95% CI: 0.15-0.71)]. There was also a statistically significant association between VA and microCT connectivity (Conn.) (r=0.80; P<0.01) and connectivity density (Conn. D) (r=0.76; P<0.01). These results encourage further studies aimed at evaluating the potential use of VA for the diagnosis of osteoporosis as a relatively low-cost and radiation-free alternative to DXA.
Bibliography:ORCID: Paulo Moraes Agnollitto, 0000-0003-1818-3266; Guilherme de Araújo Braz, 0000-0003-3650-6145; Francisco José Albuquerque de Paula, 0000-0003-1262-3486; Antonio Adilton Oliveira Carneiro, 0000-0002-1752-7170; Marcello Henrique Nogueira-Barbosa, 0000-0002-7436-5315.
ISSN:2223-4292
2223-4306
DOI:10.21037/qims-20-610