GLANCE (GLare ANnual Classes Evaluation): An approach for a simplified spatial glare evaluation
GLANCE (GLare ANnual Classes Evaluation) is a simplified method to evaluate glare conditions over a grid of points in a space on an annual basis. The method is based on three methodological assumptions: (i) the vertical illuminance (Ev) is adopted as the parameter to estimate the daylight glare cond...
Saved in:
Published in | Building and environment Vol. 186; p. 107375 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English |
Published |
Oxford
Elsevier Ltd
01.12.2020
Elsevier BV |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | GLANCE (GLare ANnual Classes Evaluation) is a simplified method to evaluate glare conditions over a grid of points in a space on an annual basis. The method is based on three methodological assumptions: (i) the vertical illuminance (Ev) is adopted as the parameter to estimate the daylight glare condition in each point of the space; (ii) daylight glare conditions are expressed in terms of Daylight Glare Comfort Classes (DGCCs); (iii) the annual time-series of Ev and DGP for a single reference point are calculated and correlated to determine the DGCC of each point.
The method allows faster glare analyses to be performed, compared to the time needed for spatio-temporal analyses using DGP. To describe the method and demonstrate its accuracy, a study was carried out using a sample space with three orientations (East, South, and West) and a glazing with various light transmittances in the range 0.05-0.75. A grid of 9 viewpoints, with 5 view directions, was assumed, for a total of 2160 combinations. The performance of the GLANCE method proved to be robust in estimating the DGCCs for the cases analysed, as shown by the Youden index, which was higher than 0.85 for over 90% of the cases considered.
•GLANCE (GLare ANnual Classes Evaluation) allows spatio-temporal glare analyses.•The eye-level vertical illuminance at each viewpoint is used to assess DGP classes.•The performance of using Ev instead of DGP values is calculated and discussed.•The diagnostic performance relative to 2160 cases of a side-lit office is assessed.•GLANCE allows faster glare analyses compared to calculation of DGP annual profiles. |
---|---|
ISSN: | 0360-1323 1873-684X |
DOI: | 10.1016/j.buildenv.2020.107375 |