Sensitivity of three thyrotropin receptor antibody assays in thyroid-associated orbitopathy

Thyrotropin receptor autoantibodies (TSH-RAb) are indispensable biomarkers in the laboratory assessment of thyroid-associated orbitopathy (TAO). Clinical sensitivity of three different assays for TSH-R-Ab determination was evaluated in patients with TAO. 87 consecutive TAO patients were enrolled and...

Full description

Saved in:
Bibliographic Details
Published inJournal of medical biochemistry Vol. 41; no. 2; pp. 211 - 220
Main Authors Sarić-Matutinović, Marija, Diana, Tanja, Nedeljković-Beleslin, Biljana, Ćirić, Jasmina, Žarković, Miloš, Perović-Blagojević, Iva, Kahaly, George J, Ignjatović, Svetlana
Format Journal Article
LanguageEnglish
Published Serbia Society of Medical Biochemists of Serbia, Belgrade 08.04.2022
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Thyrotropin receptor autoantibodies (TSH-RAb) are indispensable biomarkers in the laboratory assessment of thyroid-associated orbitopathy (TAO). Clinical sensitivity of three different assays for TSH-R-Ab determination was evaluated in patients with TAO. 87 consecutive TAO patients were enrolled and their serum samples analyzed in parallel with three assays. An ECLIA competitive binding and a chemiluminescent bridge immunoassay were used to measure total and binding TSH-R-Ab concentration, while their functional activity was determined using a stimulatory TSH-R-Ab (TSAb) cellbased bioassay. Compared to the two binding assays (ECLIA p<0.001, bridge p=0.003), the TSAb bioassay was more sensitive pertaining to the positive detection of TSH-R-Ab in TAO patients. No difference (p=0.057) was noted between the ECLIA and bridge assays regarding sensitivity rate. All patients with active and/or moderate-to-severe TAO tested positive in the TSAb bioassay (100% and 100%, respectively), while the positivity rates for bridge and ECLIA binding assays were 89.7% and 82.1% for active TAO, and 90.2% and 86.3% for severe TAO, respectively. Negative predictive values of the bioassay, bridge, and ECLIA assays were 100%, 75%, and 71%, respectively for active TAO, and 100%, 86%, and 71%, respectively for moderate-to-severe TAO. The superiority of the bioassay was most prominent in euthyroid (ET) TAO. Positivity rates of the TSAb bioassay, bridge and ECLIA binding assays were 89.6%, 75%, and 64.6%, respectively for inactive TAO; 86.1%, 69.4%, and 52.8%, respectively for mild TAO; 87.5%, 62.5%, and 12.5%, respectively for euthyroid TAO. The bridge assay correlated better with the ECLIA binding assay (r=0.893, p<0.001), compared to the bioassay (r=0.669, p<0.001). In patients with TAO of various activity and severity, the TSAb bioassay demonstrates a superior clinical performance compared to both ECLIA and bridge binding assays.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
Correspondence to: MSc Marija Saric Matutinovic, Vojvode Stepe 450, Belgrade, Serbia, +3816415279 marija.saric@pharmacy.bg.ac.rs
ISSN:1452-8258
1452-8266