Screening Tool for Paroxysmal Atrial Fibrillation Based on a Deep-Learning Algorithm Using Printed 12-Lead Electrocardiographic Records during Sinus Rhythm

Recent advancements in artificial intelligence (AI) have significantly improved atrial fibrillation (AF) detection using electrocardiography (ECG) data obtained during sinus rhythm (SR). However, the utility of printed ECG (pECG) records for AF detection, particularly in developing countries, remain...

Full description

Saved in:
Bibliographic Details
Published inReviews in cardiovascular medicine Vol. 25; no. 7; p. 242
Main Authors Zhou, Yang, Zhang, Deyun, Chen, Yu, Geng, Shijia, Wei, Guodong, Tian, Ying, Shi, Liang, Wang, Yanjiang, Hong, Shenda, Liu, Xingpeng
Format Journal Article
LanguageEnglish
Published Singapore IMR Press 01.07.2024
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Recent advancements in artificial intelligence (AI) have significantly improved atrial fibrillation (AF) detection using electrocardiography (ECG) data obtained during sinus rhythm (SR). However, the utility of printed ECG (pECG) records for AF detection, particularly in developing countries, remains unexplored. This study aims to assess the efficacy of an AI-based screening tool for paroxysmal AF (PAF) using pECGs during SR. We analyzed 5688 printed 12-lead SR-ECG records from 2192 patients admitted to Beijing Chaoyang Hospital between May 2011 to August 2022. All patients underwent catheter ablation for PAF (AF group) or other electrophysiological procedures (non-AF group). We developed a deep learning model to detect PAF from these printed SR-ECGs. The 2192 patients were randomly assigned to training (1972, 57.3% with PAF), validation (108, 57.4% with PAF), and test datasets (112, 57.1% with PAF). We developed an applet to digitize the printed ECG data and display the results within a few seconds. Our evaluation focused on sensitivity, specificity, accuracy, F1 score, the area under the receiver-operating characteristic curve (AUROC), and precision-recall curves (PRAUC). The PAF detection algorithm demonstrated strong performance: sensitivity 87.5%, specificity 66.7%, accuracy 78.6%, F1 score 0.824, AUROC 0.871 and PRAUC 0.914. A gradient-weighted class activation map (Grad-CAM) revealed the model's tailored focus on different ECG areas for personalized PAF detection. The deep-learning analysis of printed SR-ECG records shows high accuracy in PAF detection, suggesting its potential as a reliable screening tool in real-world clinical practice.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
These authors contributed equally.
ISSN:1530-6550
2153-8174
2153-8174
DOI:10.31083/j.rcm2507242