Aortic Valve Replacement With the St. Jude Medical Prosthesis and Fixed Dose Anticoagulation

Over a 10‐year period, between 1986 and 1996, 865 patients underwent primary aortic valve replacement (AVR) with the St. Jude Medical mechanical prosthesis. Patients who had undergone valve replacement with a different type of prosthesis previously were excluded from this study. Patient age ranged f...

Full description

Saved in:
Bibliographic Details
Published inJournal of cardiac surgery Vol. 12; no. 6; pp. 363 - 370
Main Authors Katircioglu, S. Fehmi, Yamak, Birol, Ulus, A. Tulga, Iscan, H. Zafer, Mavitas, Binali, Tasdemir, Oguz
Format Journal Article
LanguageEnglish
Published Oxford, UK Blackwell Publishing Ltd 01.11.1997
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Over a 10‐year period, between 1986 and 1996, 865 patients underwent primary aortic valve replacement (AVR) with the St. Jude Medical mechanical prosthesis. Patients who had undergone valve replacement with a different type of prosthesis previously were excluded from this study. Patient age ranged from 11 to 79 years. The mean age was 42.9 ± 14.54. The gender distribution was 396 men (45.8%) and 469 women (54.2%). All patients received 2.5 mg/day Coumadin after extubation. A combination of the antiagregant therapy (Dypridamole 3 × 75 mg/day, Asprine 100 mg/day) was added after removal of the chest tubes. The dosage of Coumadin was maintained constant regardless of the prothrombin time (PT) or cardiac rhythm. There were 101 valve‐related complications (4.2% per patient year [ppy]) occurring in the late follow‐up period. Of these complications; 38 were anticoagulant‐related hemorrhage (1.58% ppy), 3 were paravalvular leak (0.12% ppy), and 36 were thromboembolism (1.4% ppy). There were 24 reoperations (0.99% ppy) and 17 late deaths. The linearized late mortality rate was 0.7% ppy. Long‐term survival estimates at 5 and 10 years were 97.14 ± 0.82% and 94.86 ± 1.54%, respectively. We conclude from the data that the St. Jude Medical valve may allow the use of a low level of anticoagulation. This study shows that fixed dose oral anticoagulation does not increase the rate of thromboembolism in patients with the St. Jude aortic valve. This protocol does not result in reduction of bleeding complications, however.
Bibliography:istex:92864CA3538F7AB4D6B5542EFED3C88A0DC33241
ArticleID:JOCS363
ark:/67375/WNG-ZN23TDBV-4
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0886-0440
1540-8191
DOI:10.1111/j.1540-8191.1997.tb00152.x