Visualization and measurement of refrigerant flow in compression-type refrigerator by neutron radiography

The refrigerant two-phase flows in a capillary tube and a distributor used in a compression-type refrigerator were visualized by real-time neutron radiography. The thermal neutron radiography system of JRR-3M at the Japan Atomic Energy Research Institute was used. In the visualization experiments of...

Full description

Saved in:
Bibliographic Details
Published inNuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Vol. 424; no. 1; pp. 98 - 103
Main Authors Asano, H, Takenaka, N, Fujii, T, Shibata, Y, Ebisu, T, Matsubayashi, M
Format Journal Article
LanguageEnglish
Published Elsevier B.V 11.03.1999
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The refrigerant two-phase flows in a capillary tube and a distributor used in a compression-type refrigerator were visualized by real-time neutron radiography. The thermal neutron radiography system of JRR-3M at the Japan Atomic Energy Research Institute was used. In the visualization experiments of the two-phase flow in the capillary tube of 2 mm I.D., a cooled CCD camera was used, and the axial one-dimensional distributions of void fraction were measured. For the distributor, a high sensitivity video camera with a silicone intensified target tube was used. From the visualized images, the refrigerant behaviors in the distributor were clearly shown, and the liquid fraction in each tube was measured. As a result, it was shown that the refrigerant behaviors in the distributor effected the distributing performance of the refrigerant flow.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-2
ObjectType-Feature-1
content type line 23
SourceType-Conference Papers & Proceedings-1
ObjectType-Conference-3
ISSN:0168-9002
1872-9576
DOI:10.1016/S0168-9002(98)01278-9