Visualization and measurement of refrigerant flow in compression-type refrigerator by neutron radiography
The refrigerant two-phase flows in a capillary tube and a distributor used in a compression-type refrigerator were visualized by real-time neutron radiography. The thermal neutron radiography system of JRR-3M at the Japan Atomic Energy Research Institute was used. In the visualization experiments of...
Saved in:
Published in | Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Vol. 424; no. 1; pp. 98 - 103 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | English |
Published |
Elsevier B.V
11.03.1999
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | The refrigerant two-phase flows in a capillary tube and a distributor used in a compression-type refrigerator were visualized by real-time neutron radiography. The thermal neutron radiography system of JRR-3M at the Japan Atomic Energy Research Institute was used. In the visualization experiments of the two-phase flow in the capillary tube of 2
mm I.D., a cooled CCD camera was used, and the axial one-dimensional distributions of void fraction were measured. For the distributor, a high sensitivity video camera with a silicone intensified target tube was used. From the visualized images, the refrigerant behaviors in the distributor were clearly shown, and the liquid fraction in each tube was measured. As a result, it was shown that the refrigerant behaviors in the distributor effected the distributing performance of the refrigerant flow. |
---|---|
Bibliography: | ObjectType-Article-2 SourceType-Scholarly Journals-2 ObjectType-Feature-1 content type line 23 SourceType-Conference Papers & Proceedings-1 ObjectType-Conference-3 |
ISSN: | 0168-9002 1872-9576 |
DOI: | 10.1016/S0168-9002(98)01278-9 |