Impact of explanted valve type on aortic valve reoperations: nationwide UK experience

This nationwide retrospective cohort study assessed the impact of the explanted valve type on reoperative outcomes in aortic valve surgery within the UK over a 23-year period. Data were sourced from the National Institute for Cardiovascular Outcomes Research (NICOR) database. All patients undergoing...

Full description

Saved in:
Bibliographic Details
Published inEuropean journal of cardio-thoracic surgery Vol. 65; no. 2
Main Authors Narayan, Pradeep, Dong, Tim, Dimagli, Arnaldo, Fudulu, Daniel P, Chan, Jeremy, Sinha, Shubhra, Angelini, Gianni D
Format Journal Article
LanguageEnglish
Published Germany Oxford University Press 01.02.2024
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:This nationwide retrospective cohort study assessed the impact of the explanted valve type on reoperative outcomes in aortic valve surgery within the UK over a 23-year period. Data were sourced from the National Institute for Cardiovascular Outcomes Research (NICOR) database. All patients undergoing first-time isolated reoperative aortic valve replacement between 1996 and 2019 in the UK were included. Concomitant procedures, homograft implantation or aortic root enlargement were excluded. Propensity score matching was utilized to compare outcomes and risk factors for in-hospital mortality was evaluated through multivariable logistic regression. Final model selection was conducted using Akaike Information Criterion through bootstrapping. The primary end point was in-hospital mortality, and secondary end points included postoperative morbidities. Out of 2371 patients, 24.9% had mechanical and 75% had bioprosthetic valves implanted during the primary procedure. Propensity matched groups of 324 patients each, were compared. In-hospital mortality for mechanical and bioprosthetic valve explants was 7.1% and 5.9%, respectively (P = 0.632). On multivariable logistic regression analysis, valve type was not a risk factor for mortality [odds ratio (OR) 0.62, 95% confidence interval (CI) 0.37-1.05; P = 0.1]. Age (OR 1.03, 95% CI 1.01-1.05; P < 0.05), left ventricular ejection fraction (OR 1.62, 95% CI 1.08-2.42; P < 0.05), creatinine ≥ 200 mg/dl (OR 2.21, 95% CI 1.17-4.04; P < 0.05) and endocarditis (OR 2.66, 95% CI 1.71-4.14; P < 0.05) emerged as risk factors for mortality. The type of valve initially implanted (mechanical or bioprosthetic) did not determine mortality. Instead, age, left ventricular ejection fraction, renal impairment and endocarditis were significant risk factors for in-hospital mortality.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
Pradeep Narayan and Tim Dong contributed equally to this work.
ISSN:1873-734X
1010-7940
1873-734X
DOI:10.1093/ejcts/ezae031