Predicting the viscosity of halogenated hydrocarbon mixtures

The viscosity of three refrigerant mixtures, namely R125–R134a, R152a–R134a and propane–R134a, has been evaluated by a prediction method based on kinetic theory. The method has no adjustable parameters and, in essence, relies upon knowledge of the viscosity of the pure components to predict the visc...

Full description

Saved in:
Bibliographic Details
Published inFluid phase equilibria Vol. 199; no. 1; pp. 295 - 306
Main Author Vesovic, V.
Format Journal Article Conference Proceeding
LanguageEnglish
Published Amsterdam Elsevier B.V 30.06.2002
Elsevier Science
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The viscosity of three refrigerant mixtures, namely R125–R134a, R152a–R134a and propane–R134a, has been evaluated by a prediction method based on kinetic theory. The method has no adjustable parameters and, in essence, relies upon knowledge of the viscosity of the pure components to predict the viscosity of a mixture by means of rigid-sphere formalism. The predictions have been compared with experimental data available along the liquid saturation line. The viscosity of R125–R134a and R134a–R152a mixtures has been reproduced remarkably well, to within ±4%. The viscosity of propane–R134a mixture was underpredicted at the lowest temperature (250 K) by 20%. The failure of the method to predict the viscosity of propane–R134a more accurately, is primarily attributed to the strong non-ideality of the propane–R134a mixture.
ISSN:0378-3812
1879-0224
DOI:10.1016/S0378-3812(01)00802-0