Measurement of non-compensated angular dispersion and the subsequent temporal lengthening of femtosecond pulses in a CPA laser

Closed analytical formulae are given for the residual angular dispersion resulted from the non-parallel surfaces of both a grating pair and a prism pair pulse compressor. Accurate measurements of the angular dispersion of pulses leaving the misaligned pulse compressors agree well with the first prin...

Full description

Saved in:
Bibliographic Details
Published inOptics communications Vol. 248; no. 1-3; pp. 201 - 209
Main Authors Osvay, K., Kovács, A.P., Kurdi, G., Heiner, Z., Divall, M., Klebniczki, J., Ferincz, I.E.
Format Journal Article
LanguageEnglish
Published Amsterdam Elsevier B.V 01.04.2005
Elsevier Science
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Closed analytical formulae are given for the residual angular dispersion resulted from the non-parallel surfaces of both a grating pair and a prism pair pulse compressor. Accurate measurements of the angular dispersion of pulses leaving the misaligned pulse compressors agree well with the first principle simulation curves. The corresponding lengthening of the transform limited 18 fs pulses was also determined. Finally, it is experimentally proved that by simultaneous monitoring of angular dispersion and pulse duration, the stretcher–compressor system of a chirped pulse amplification laser can be aligned very precisely.
ISSN:0030-4018
1873-0310
DOI:10.1016/j.optcom.2004.11.099