Equivalent circuit model and characteristic parameters for AC PDP discharge cells

In this paper, an equivalent circuit model for discharge cells of alternating current plasma display panel (AC PDP) is developed. In this model, a voltage controlled switch is introduced to describe the breakdown process of the gas discharge. And two zener diodes are introduced to describe the susta...

Full description

Saved in:
Bibliographic Details
Published inDisplays Vol. 28; no. 4-5; pp. 181 - 185
Main Authors Liang, Zhi-Hu, Liu, Chun-Liang, Liu, Zu-Jun
Format Journal Article
LanguageEnglish
Published Oxford Elsevier B.V 01.12.2007
Elsevier
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:In this paper, an equivalent circuit model for discharge cells of alternating current plasma display panel (AC PDP) is developed. In this model, a voltage controlled switch is introduced to describe the breakdown process of the gas discharge. And two zener diodes are introduced to describe the sustain process of the gas discharge. Three internal discharge characteristic parameters, the breakdown voltage of discharge gap, the minimum sustain voltage of discharge gap and the discharge cell capacitance ratio, are proposed. The formulas for expressing external discharge characteristic parameters by internal discharge characteristic parameters are derived. The experimental method for measuring internal characteristic parameters is developed and the measurement results for a macro discharge cell are presented.