Enhancing stormwater treatment through ultrafiltration: Impact of cleaning chemicals and backwash duration on membrane efficiency

Abstract The effect of chemical cleaning and regular backwashing on the efficiency of an ultrafiltration membrane fouled during stormwater treatment was studied. Increasing backwash time from 30 to 60 s resulted in an increase in productivity by 20%. However, the productivity was highest when a back...

Full description

Saved in:
Bibliographic Details
Published inWater Reuse (London, England) Vol. 13; no. 4; pp. 634 - 646
Main Authors Kaykhaii, Saida, Herrmann, Inga, Hedström, Annelie, Nordqvist, Kerstin, Heidfors, Ingemar, Viklander, Maria
Format Journal Article
LanguageEnglish
Published IWA Publishing 01.12.2023
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Abstract The effect of chemical cleaning and regular backwashing on the efficiency of an ultrafiltration membrane fouled during stormwater treatment was studied. Increasing backwash time from 30 to 60 s resulted in an increase in productivity by 20%. However, the productivity was highest when a backwash time of 45 s was used (3% higher than using 60 s). Chemical cleaning was carried out using an alkaline solution (NaOH with or without NaOCl) followed by acid washing with HCl. The addition of NaOCl to the cleaning chemical did not significantly increase the efficiency of chemical cleaning, and the average pure water permeability increase was 97 ± 13 LMH bar−1 after chemical cleaning with NaOH followed by HCl and 117 ± 15 LMH bar−1 after chemical cleaning with NaOH + NaOCl followed by HCl, on average. In addition, reversibility after chemical cleaning was 96 ± 67%, on average. The result from scanning electron microscopy showed that at the end of the experiments, inorganic foulants existed in both the inner layer (feed side) and the outer layer (permeate side) of the membrane.
ISSN:2709-6092
2709-6106
2709-6106
DOI:10.2166/wrd.2023.106