Within-subject and between-subject biological variation of first morning void urine amino acids in 12 healthy subjects

Background Urine amino acid analysis is used for the assessment of various diseases. The aim of this study was to estimate the valid biological variation (BV) components (within- and between-subjects) required for the safe clinical application of free urine amino acids. Methods First morning void ur...

Full description

Saved in:
Bibliographic Details
Published inClinical chemistry and laboratory medicine Vol. 58; no. 11; pp. 1901 - 1909
Main Authors Alp, Hamit Hakan, Akbay, Halil İbrahim, Çokluk, Erdem, Huyut, Zubeyir, Keskin, Sıddık, Şekeroğlu, Mehmet Ramazan
Format Journal Article
LanguageEnglish
Published Germany De Gruyter 01.11.2020
Walter De Gruyter & Company
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background Urine amino acid analysis is used for the assessment of various diseases. The aim of this study was to estimate the valid biological variation (BV) components (within- and between-subjects) required for the safe clinical application of free urine amino acids. Methods First morning void urine samples were taken from 12 healthy subjects (five females, seven males) once a week for 10 consecutive weeks, and amino acid analysis was performed using an Agilent 6470 triple quadrupole tandem mass spectrometer instrument. The obtained data were subjected to normality, outlier and variance homogeneity analyses prior to coefficient of variation (CV) analysis. Within- and between-subject BV values (CVI and CVG) of 39 amino acids were determined for all subjects. In addition, the index of individuality (II), reference change value (RCV), imprecision, bias and total error were estimated using BV data obtained from our study. Results The CVI values ranged from 8.9 (histidine) to 36.8% (trans-4-hydroxyprolin), while the CVG values ranged from 25.0 (1-methyl-L-histidine) to 63.3% (phenylalanine). The II value of most amino acids was less than 0.6 and ranged between 0.21 and 0.88. The imprecision, bias and total error ranged between 4.45 and 16.6, between 7.69 and 16.6, and between 18.4 and 43.2, respectively. Conclusions This study, designed according to a rigorous protocol, has the feature of being the first to give information about BV data of urine amino acids. We believe that the reference intervals have a limitation in the evaluation of consecutive results from an individual, so the use of RCV would be more appropriate.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:1434-6621
1437-4331
1437-4331
DOI:10.1515/cclm-2020-0249