Very late stent thrombosis 5 years after IVUS-guided drug-eluting stent implantation

It is well accepted that drug-eluting stents (DES) are effective in reducing restenosis, although implantation of DES may result in increased occurrence of stent thrombosis. The study describes the case of a patient with very late stent thrombosis (VLST) despite intravascular ultrasound (IVUS) contr...

Full description

Saved in:
Bibliographic Details
Published inBlood coagulation & fibrinolysis Vol. 23; no. 7; p. 666
Main Authors Sauter, Reinhard J, Steeg, Martin, Bocksch, Wolfgang, Schreieck, Jürgen, Gawaz, Meinrad, Langer, Harald F
Format Journal Article
LanguageEnglish
Published England 01.10.2012
Subjects
Online AccessGet more information

Cover

Loading…
Abstract It is well accepted that drug-eluting stents (DES) are effective in reducing restenosis, although implantation of DES may result in increased occurrence of stent thrombosis. The study describes the case of a patient with very late stent thrombosis (VLST) despite intravascular ultrasound (IVUS) control after implantation of a paclitaxel-eluting stent, an adequate response to antiplatelet therapy, and the lack of distinct risk factors for VLST. Stent thrombosis remains a serious complication after stent implantation even after prolonged time, and studies are urgently needed to optimize diagnosis and treatment of VLST.
AbstractList It is well accepted that drug-eluting stents (DES) are effective in reducing restenosis, although implantation of DES may result in increased occurrence of stent thrombosis. The study describes the case of a patient with very late stent thrombosis (VLST) despite intravascular ultrasound (IVUS) control after implantation of a paclitaxel-eluting stent, an adequate response to antiplatelet therapy, and the lack of distinct risk factors for VLST. Stent thrombosis remains a serious complication after stent implantation even after prolonged time, and studies are urgently needed to optimize diagnosis and treatment of VLST.
Author Sauter, Reinhard J
Schreieck, Jürgen
Bocksch, Wolfgang
Steeg, Martin
Langer, Harald F
Gawaz, Meinrad
Author_xml – sequence: 1
  givenname: Reinhard J
  surname: Sauter
  fullname: Sauter, Reinhard J
  organization: Department of Cardiology and Cardiovascular Medicine, University Clinic of Tuebingen, Tuebingen, Germany
– sequence: 2
  givenname: Martin
  surname: Steeg
  fullname: Steeg, Martin
– sequence: 3
  givenname: Wolfgang
  surname: Bocksch
  fullname: Bocksch, Wolfgang
– sequence: 4
  givenname: Jürgen
  surname: Schreieck
  fullname: Schreieck, Jürgen
– sequence: 5
  givenname: Meinrad
  surname: Gawaz
  fullname: Gawaz, Meinrad
– sequence: 6
  givenname: Harald F
  surname: Langer
  fullname: Langer, Harald F
BackLink https://www.ncbi.nlm.nih.gov/pubmed/22885763$$D View this record in MEDLINE/PubMed
BookMark eNo1j8tOAjEUQBujEUH_wJj-wGDb2-ltl0p8kGBcCGxJh97BMfMgbWfB37sQV2d1TnKm7LIfemLsXoq5FA4fP54Xc1EJCQTKQmlAluKC3UiNUJQIMGHTlH6EEKAtXrOJUtaWaOCGrbcUT7z1mXjK1Geev-PQVUNqEi_5iXxM3NeZIl9uN1_FYWwCBR7ieCioHXPTH85e0x1b32efm6G_ZVe1bxPdnTljm9eX9eK9WH2-LRdPq2IPILEIWKJEp7Vze0do9D5UVBvrauU1VNI4DWQVojBIXtREmiAo9EaAE8GqGXv46x7HqqOwO8am8_G0-99Tv4PyUvs
ContentType Journal Article
DBID CGR
CUY
CVF
ECM
EIF
NPM
DOI 10.1097/MBC.0b013e3283563150
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
DatabaseTitleList MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Medicine
Anatomy & Physiology
EISSN 1473-5733
ExternalDocumentID 22885763
Genre Research Support, Non-U.S. Gov't
Journal Article
Case Reports
GroupedDBID ---
.-D
.Z2
0R~
23N
4Q1
4Q2
4Q3
53G
5GY
5RE
5VS
6J9
71W
8L-
AAAAV
AAHPQ
AAIQE
AAMTA
AARTV
AASCR
AAYEP
ABASU
ABBUW
ABDIG
ABJNI
ABOCM
ABVCZ
ABXVJ
ABZAD
ACDDN
ACEWG
ACGFS
ACILI
ACWDW
ACWRI
ACXJB
ACXNZ
ADFPA
ADGGA
ADHPY
ADNKB
AE3
AE6
AEETU
AENEX
AFDTB
AHQNM
AHVBC
AINUH
AJIOK
AJNWD
AJNYG
AJZMW
ALMA_UNASSIGNED_HOLDINGS
ALMTX
AMJPA
AMKUR
AMNEI
AOHHW
AWKKM
BQLVK
BS7
C45
CAG
CGR
COF
CS3
CUY
CVF
DIWNM
DU5
DUNZO
E.X
EBS
ECM
EEVPB
EIF
EJD
EX3
F5P
FCALG
FL-
GNXGY
GQDEL
H0~
HLJTE
HZ~
IKREB
IN~
IPNFZ
JF9
JG8
JK3
JK8
K8S
KD2
L-C
N9A
NPM
N~M
O9-
OAG
OAH
OCUKA
ODA
OLG
OLW
OPUJH
ORVUJ
OUVQU
OVD
OVDNE
OWU
OWV
OWW
OWX
OWY
OWZ
OXXIT
P-K
R58
RIG
RLZ
S4R
S4S
T8P
TEORI
TSPGW
V2I
VVN
W3M
WOQ
WOW
X3V
X3W
XXN
XYM
YFH
ZFV
ZZMQN
ID FETCH-LOGICAL-c3317-d7571794499c9e764cdbef689f2a43b16943e8277067ea0fee4e3d27a60390d82
IngestDate Sat Sep 28 07:51:44 EDT 2024
IsPeerReviewed true
IsScholarly true
Issue 7
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c3317-d7571794499c9e764cdbef689f2a43b16943e8277067ea0fee4e3d27a60390d82
PMID 22885763
ParticipantIDs pubmed_primary_22885763
PublicationCentury 2000
PublicationDate 2012-October
PublicationDateYYYYMMDD 2012-10-01
PublicationDate_xml – month: 10
  year: 2012
  text: 2012-October
PublicationDecade 2010
PublicationPlace England
PublicationPlace_xml – name: England
PublicationTitle Blood coagulation & fibrinolysis
PublicationTitleAlternate Blood Coagul Fibrinolysis
PublicationYear 2012
SSID ssj0003487
Score 2.006832
Snippet It is well accepted that drug-eluting stents (DES) are effective in reducing restenosis, although implantation of DES may result in increased occurrence of...
SourceID pubmed
SourceType Index Database
StartPage 666
SubjectTerms Aged
Coronary Angiography
Coronary Thrombosis - diagnostic imaging
Coronary Thrombosis - etiology
Drug-Eluting Stents - adverse effects
Female
Humans
Paclitaxel - administration & dosage
Risk Factors
Treatment Outcome
Ultrasonography
Title Very late stent thrombosis 5 years after IVUS-guided drug-eluting stent implantation
URI https://www.ncbi.nlm.nih.gov/pubmed/22885763
Volume 23
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lb9NAEF6lICEuCFreD-0BcYkMsdf2ro9tBCqV0gMkpbdq1zu2oiZ21DqH9H_0_zL7cLoqBQEXK_LKK8vzZXZe3wwh71OtJFMSIgVaRGklICoyDlGi0ZfIYqgKy4WZHOeHs_ToNDsdDK6DqqV1pz6WV3fySv5HqngP5WpYsv8g2e2meAN_o3zxihLG61_J-AQuNsMFWotDlFXT2aE7S9WaHiPZcIMYvvQzwL-ezL5H9Xqu0bzUF-s6AvNaNpJgnpsvVwvZBEn5PstrqtqHZStrP-TLAqUyLIGmtb1MtgEaufYTPr7BvDFMriDf1AHUnhfUN_q2BYrl-aUbRPWjXVS19GeozQohwubgNPWRyeUfjA1JNAxRxMm22A1PGKdWU84i03kx1LuOZ-zxxQMlmrs5LL8od9c0eHIw7qO3pldczmLXuTaQ92ppBZ4kQmRef_559VbL7X5ph-xwYdTmsQkB-eOdoYvXczAL_umu1zEdpv0Wt7wVa7VMH5NH3t2g-w47T8gAml2yt9_Irl1u6AdqC4BtZmWXPJj4Oos9MjXIogZZ1CKE3iCLZtQii1pk0QBZNESWfy5E1lMy-_J5Oj6M_PyNqGRoVkaaZ9zoa3SKywJ4npZaQZWLokpkylScFykDkXCOFg_IUQWQAtMJl_mIFSMtkmfkXtM28IJQDSLTuhCZUmkqQeEewvBetACZMR2_JM_dZzpbuSYrZ_0HfPXbldfk4Q3Y3pD7Ff6r4S2aiJ16Z0X2E643Zp8
link.rule.ids 786
linkProvider National Library of Medicine
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Very+late+stent+thrombosis+5+years+after+IVUS-guided+drug-eluting+stent+implantation&rft.jtitle=Blood+coagulation+%26+fibrinolysis&rft.au=Sauter%2C+Reinhard+J&rft.au=Steeg%2C+Martin&rft.au=Bocksch%2C+Wolfgang&rft.au=Schreieck%2C+J%C3%BCrgen&rft.date=2012-10-01&rft.eissn=1473-5733&rft.volume=23&rft.issue=7&rft.spage=666&rft_id=info:doi/10.1097%2FMBC.0b013e3283563150&rft_id=info%3Apmid%2F22885763&rft_id=info%3Apmid%2F22885763&rft.externalDocID=22885763