Transmission Line Approach to Calculate the Shielding Effectiveness of an Enclosure With Double-Layer Frequency Selective Surface
The shielding effectiveness (SE) of a metallic enclosure with double-layer frequency selective surface (DLFSS) has been calculated using a transmission line theory-based analytical formulation. The DLFSS layer placed on the front and back sides of the enclosure consists of a Greek cross aperture arr...
Saved in:
Published in | IEEE transactions on electromagnetic compatibility Vol. 57; no. 6; pp. 1736 - 1739 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
New York
IEEE
01.12.2015
The Institute of Electrical and Electronics Engineers, Inc. (IEEE) |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | The shielding effectiveness (SE) of a metallic enclosure with double-layer frequency selective surface (DLFSS) has been calculated using a transmission line theory-based analytical formulation. The DLFSS layer placed on the front and back sides of the enclosure consists of a Greek cross aperture array. The equivalent circuit method and an empirical method are used to calculate the impedance of the Greek cross FSS. Then, the SE is calculated for various incidence and polarization angles. Calculated results are compared with the measured and numerical simulation results. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0018-9375 1558-187X |
DOI: | 10.1109/TEMC.2015.2453333 |