Comparing fully automated AI body composition biomarkers at differing virtual monoenergetic levels using dual-energy CT

Purpose To investigate the behavior of artificial intelligence (AI) CT-based body composition biomarkers at different virtual monoenergetic imaging (VMI) levels using dual-energy CT (DECT). Methods This retrospective study included 88 contrast-enhanced abdominopelvic CTs acquired with rapid-kVp swit...

Full description

Saved in:
Bibliographic Details
Published inAbdominal imaging Vol. 50; no. 6; pp. 2758 - 2769
Main Authors Toia, Giuseppe V., Garret, John W., Rose, Sean D., Szczykutowicz, Timothy P., Pickhardt, Perry J.
Format Journal Article
LanguageEnglish
Published New York Springer US 01.06.2025
Springer Nature B.V
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Purpose To investigate the behavior of artificial intelligence (AI) CT-based body composition biomarkers at different virtual monoenergetic imaging (VMI) levels using dual-energy CT (DECT). Methods This retrospective study included 88 contrast-enhanced abdominopelvic CTs acquired with rapid-kVp switching DECT. Images were reconstructed into five VMI levels (40, 55, 70, 85, 100 keV). Fully automated algorithms for quantifying CT number (HU) in abdominal fat (subcutaneous and visceral), skeletal muscle, bone, calcium (abdominal Agatston score), and organ size (area or volume) were applied. Biomarker median difference relative to 70 keV and interquartile range were reported by energy level to characterize variation. Linear regression was performed to calibrate non-70 keV data and to estimate their equivalent 70 keV biomarker attenuation values. Results Relative to 70 keV, absolute median differences in attenuation-based biomarkers (excluding Agatston score) ranged 39–358, 12–102, 5–48, 9–75 HU for 40, 55, 85, 100 keV, respectively. For area-based biomarkers, differences ranged 6–15, 3–4, 2–7, 0–5 cm 2 for 40, 55, 85, 100 keV. For volume-based biomarkers, differences ranged 12–34, 8–68, 12–52, 1–57 cm 3 for 40, 55, 85, 100 keV. Agatston score behavior was more spurious with median differences ranging 70–204 HU. In general, VMI < 70 keV showed more variation in median biomarker measurement than VMI > 70 keV. Conclusion This study characterized the behavior of a fully automated AI CT biomarker toolkit across varying VMI levels obtained with DECT. The data showed relatively little biomarker value change when measured at or greater than 70 keV. Lower VMI datasets should be avoided due to larger deviations in measured value as compared to 70 keV, a level considered equivalent to conventional 120 kVp exams.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:2366-0058
2366-004X
2366-0058
DOI:10.1007/s00261-024-04733-7