Power Superposition Control Method of Power for Position Sensor Using a Single‐Phase Transformer on the Power Lines of a PMSM

ABSTRACT In this paper, a method for extracting constant power from transformers on power lines is presented. The secondary side power equation is obtained based on the circuit equation for power superposition using a single‐phase transformer. Using this equation, an area discrimination method of th...

Full description

Saved in:
Bibliographic Details
Published inElectrical engineering in Japan Vol. 218; no. 1
Main Authors Kiribuchi, Takeshi, Inoue, Yukinori, Morimoto, Shigeo
Format Journal Article
LanguageEnglish
Published Hoboken Wiley Subscription Services, Inc 01.03.2025
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:ABSTRACT In this paper, a method for extracting constant power from transformers on power lines is presented. The secondary side power equation is obtained based on the circuit equation for power superposition using a single‐phase transformer. Using this equation, an area discrimination method of the speed versus torque characteristics of the permanent magnet synchronous motor and a power superposition control method in the area are proposed. To validate the proposed method, the discrimination method was verified via simulation and experiment with boundary conditions. Similarly, the power superposition control method was verified via simulation and experiment, with the command current controlled using a power estimator. The results verify the discrimination and power superposition control methods.
Bibliography:Translated from Volume 144 Number 8, pages 613–621, DOI
(Denki Gakkai Ronbunshi D).
10.1541/ieejias.144.613
of
IEEJ Transactions on Industry Applications
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ISSN:0424-7760
1520-6416
DOI:10.1002/eej.23501