Distance-Coefficient-Based Imaging Accuracy Improving Method Based on the Lamb Wave
An imaging accuracy improving method is established, within which a distance coefficient including location information between sparse array configuration and the location of defect is proposed to select higher signal- to-noise ratio data from all experimental data and then to use these selected dat...
Saved in:
Published in | Chinese physics letters Vol. 34; no. 4; pp. 55 - 59 |
---|---|
Main Author | |
Format | Journal Article |
Language | English |
Published |
Chinese Physical Society and IOP Publishing Ltd
01.03.2017
|
Online Access | Get full text |
ISSN | 0256-307X 1741-3540 |
DOI | 10.1088/0256-307X/34/4/044301 |
Cover
Summary: | An imaging accuracy improving method is established, within which a distance coefficient including location information between sparse array configuration and the location of defect is proposed to select higher signal- to-noise ratio data from all experimental data and then to use these selected data for elliptical imaging. Tile relationships among imaging accuracy, distance coefficient and residual direct wave are investigated, and then the residual direct wave is introduced to make the engineering application more convenient. The effectiveness of the proposed method is evaluated experimentally by sparse transducer array of a rectangle, and the results reveal that selecting experimental data of smaller distance coefficient can effectively improve imaging accuracy. Moreover, the direct wave difference increases with the decrease of the distance coefficient, which implies that the imaging accuracy can be effectively improved by using the experimental data of the larger direct wave difference. |
---|---|
Bibliography: | An imaging accuracy improving method is established, within which a distance coefficient including location information between sparse array configuration and the location of defect is proposed to select higher signal- to-noise ratio data from all experimental data and then to use these selected data for elliptical imaging. Tile relationships among imaging accuracy, distance coefficient and residual direct wave are investigated, and then the residual direct wave is introduced to make the engineering application more convenient. The effectiveness of the proposed method is evaluated experimentally by sparse transducer array of a rectangle, and the results reveal that selecting experimental data of smaller distance coefficient can effectively improve imaging accuracy. Moreover, the direct wave difference increases with the decrease of the distance coefficient, which implies that the imaging accuracy can be effectively improved by using the experimental data of the larger direct wave difference. Shao-Jie Chen, Shao-Ping Zhou, Yong Li, Yan-Xun Xiang, Min-Xin Qi( Key Lab of Pressure Systems and Safety (MOE), East China University of Science and Technology, Shanghai 200237) 11-1959/O4 |
ISSN: | 0256-307X 1741-3540 |
DOI: | 10.1088/0256-307X/34/4/044301 |