Sub-external cavity effect and elimination method in laser self-mixing interference wave plate measurement system

Laser self-mixing interference(SMI) wave plate measurement method is a burgeoning technique for its simplicity and efficiency. But for the non-coated sample, the reflected light from the surface can seriously affect the measurement results.To analyze the reason theoretically, a self-consistent model...

Full description

Saved in:
Bibliographic Details
Published inChinese physics B Vol. 27; no. 2; pp. 349 - 354
Main Author 牛海莎;牛燕雄;宋建军
Format Journal Article
LanguageEnglish
Published Chinese Physical Society and IOP Publishing Ltd 01.02.2018
Subjects
Online AccessGet full text
ISSN1674-1056
2058-3834
DOI10.1088/1674-1056/27/2/024201

Cover

Loading…
More Information
Summary:Laser self-mixing interference(SMI) wave plate measurement method is a burgeoning technique for its simplicity and efficiency. But for the non-coated sample, the reflected light from the surface can seriously affect the measurement results.To analyze the reason theoretically, a self-consistent model for laser operation with a sub-external and an external cavity is established, and the sub-external cavity formed by the sample and a cavity mirror is proved to be the main error source.A synchronous tuning method is proposed to eliminate the sub-external cavity effect. Experiments are carried out on the synchronously tuning double external cavities self-mixing interference system, and the error of the system is in the range of -0.435°~0.387° compared with the ellipsometer. The research plays an important role in improving the performance and enlarging the application range of the laser self-mixing interference system.
Bibliography:Laser self-mixing interference(SMI) wave plate measurement method is a burgeoning technique for its simplicity and efficiency. But for the non-coated sample, the reflected light from the surface can seriously affect the measurement results.To analyze the reason theoretically, a self-consistent model for laser operation with a sub-external and an external cavity is established, and the sub-external cavity formed by the sample and a cavity mirror is proved to be the main error source.A synchronous tuning method is proposed to eliminate the sub-external cavity effect. Experiments are carried out on the synchronously tuning double external cavities self-mixing interference system, and the error of the system is in the range of -0.435°~0.387° compared with the ellipsometer. The research plays an important role in improving the performance and enlarging the application range of the laser self-mixing interference system.
11-5639/O4
self-mixing interference non-coated wave plate measurement self-consistent model
ISSN:1674-1056
2058-3834
DOI:10.1088/1674-1056/27/2/024201