Simultaneous and ultra-sensitive SERS detection of SLPI and IL-18 for the assessment of donor kidney quality using black phosphorus/gold nanohybrids

Due to the global challenge of donor kidney shortage, expanding the pool of deceased donors has been proposed to include expanded criteria donors. However, the lack of methods to precisely measure donor kidney injury and predict the outcome still leads to high discard rates and recipient complicatio...

Full description

Saved in:
Bibliographic Details
Published inOptics express Vol. 30; no. 2; pp. 1452 - 1465
Main Authors Chen, Hui, Luo, Caixia, Xing, Longqiang, Guo, Huiru, Ma, Pei, Zhang, Xuedian, Zeng, Li, Sui, Mingxing
Format Journal Article
LanguageEnglish
Published United States 17.01.2022
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Due to the global challenge of donor kidney shortage, expanding the pool of deceased donors has been proposed to include expanded criteria donors. However, the lack of methods to precisely measure donor kidney injury and predict the outcome still leads to high discard rates and recipient complications. As such, evaluation of deceased donor kidney quality is critical prior to transplantation. Biomarkers from donor urine or serum provide potential advantages for the precise measure of kidney quality. Herein, simultaneous detection of secretory leukocyte peptidase inhibitor (SLPI) and interleukin 18 (IL-18), two important kidney injury biomarkers, has been achieved, for the first time, with an ultra-high sensitivity using surface enhanced Raman scattering (SERS). Specifically, black phosphorus/gold (BP/Au) nanohybrids synthesized by depositing Au nanoparticles (NPs) onto the BP nanosheets serve as SERS-active substrates, which offer a high-density of inherent and accessible hot-spots. Meanwhile, the nanohybrids possess biocompatible surfaces for the enrichment of target biomarkers through the affinity with BP nanosheets. Quantitative detection of SLPI and IL-18 were then achieved by characterizing SERS signals of these two biomarkers. The results indicate high sensitivity and excellent reproducibility of this method. The limits of detection reach down to 1.53×10 mg/mL for SLPI and 0.23×10 mg/mL for IL-18. The limits of quantification are 5.10×10 mg/mL and 7.67×10 mg/mL for SLPI and IL-18. In addition, simultaneous detection of these biomarkers in serum was investigated, which proves the feasibility in biologic environment. More importantly, this method is powerful for detecting multiple analytes inheriting from excellent multiplexing ability of SERS. Giving that the combined assessment of SLPI and IL-18 expression level serves as an indicator of donor kidney quality and can be rapidly and reproducibly conducted, this SERS-based method holds great prospective in clinical practice.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1094-4087
1094-4087
DOI:10.1364/OE.445809