A magnetic method for testing the thickness of two-sided weakly magnetic coatings by a nonmagnetic base

The general case where the depth of the informative zone is greater than the thickness of a nonmagnetic base having a two-sided weakly magnetic coating is considered. In this case, the informative signal is determined by the thickness of the base and coating on both sides. A technique for separately...

Full description

Saved in:
Bibliographic Details
Published inRussian journal of nondestructive testing Vol. 45; no. 7; pp. 502 - 508
Main Authors Lukhvich, A. A., Luk’yanov, A. L., Kremen’kova, N. V., Shukevich, A. K.
Format Journal Article
LanguageEnglish
Published Dordrecht SP MAIK Nauka/Interperiodica 01.07.2009
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The general case where the depth of the informative zone is greater than the thickness of a nonmagnetic base having a two-sided weakly magnetic coating is considered. In this case, the informative signal is determined by the thickness of the base and coating on both sides. A technique for separately measuring the coating thickness on either side taking into account the effect of both coatings on the informative signal is proposed as applied to the magnetodynamic method.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:1061-8309
1608-3385
DOI:10.1134/S1061830909070092