A magnetic method for testing the thickness of two-sided weakly magnetic coatings by a nonmagnetic base
The general case where the depth of the informative zone is greater than the thickness of a nonmagnetic base having a two-sided weakly magnetic coating is considered. In this case, the informative signal is determined by the thickness of the base and coating on both sides. A technique for separately...
Saved in:
Published in | Russian journal of nondestructive testing Vol. 45; no. 7; pp. 502 - 508 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
Dordrecht
SP MAIK Nauka/Interperiodica
01.07.2009
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | The general case where the depth of the informative zone is greater than the thickness of a nonmagnetic base having a two-sided weakly magnetic coating is considered. In this case, the informative signal is determined by the thickness of the base and coating on both sides. A technique for separately measuring the coating thickness on either side taking into account the effect of both coatings on the informative signal is proposed as applied to the magnetodynamic method. |
---|---|
Bibliography: | ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Feature-1 content type line 23 |
ISSN: | 1061-8309 1608-3385 |
DOI: | 10.1134/S1061830909070092 |