Evaluation of Cobas Integra® 800 under simulated routine conditions in six laboratories

The new selective access analyser Cobas Integra 800 from Roche Diagnostics was evaluated in an international multicentre study at six sites. Routine simulation experiments showed good performance and full functionality of the instrument and provocation of anomalous situations generated no problems....

Full description

Saved in:
Bibliographic Details
Published inClinical chemistry and laboratory medicine Vol. 41; no. 3; pp. 365 - 381
Main Authors REDONDO, Francisco L, BERMUDEZ, Pilar, MEZIANI, Mourad, LIEBEL, Maryann, MCQUEEN, Matthew J, STOCKMANN, Wolfgang, COCCO, Claudio, COLELLA, Francesca, GRAZIANI, Maria Stella, FIEHN, Walter, HIERL, Thomas, LEMOËL, Gisèle, BELLIARD, Annemarie, MANENE, Dieudonne
Format Journal Article
LanguageEnglish
Published Berlin Walter de Gruyter 01.03.2003
New York, NY
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The new selective access analyser Cobas Integra 800 from Roche Diagnostics was evaluated in an international multicentre study at six sites. Routine simulation experiments showed good performance and full functionality of the instrument and provocation of anomalous situations generated no problems. The new features on Cobas Integra 800, namely clot detection and dispensing control, worked according to specifications. The imprecision of Cobas Integra 800 fulfilled the proposed quality specifications regarding imprecision of analytical systems for clinical chemistry with few exceptions. Claims for linearity, drift, and carry-over were all within the defined specifications, except urea linearity. Interference exists in some cases, as could be expected due to the chemistries applied. Accuracy met the proposed quality specifications, except in some special cases. Method comparisons with Cobas Integra 700 showed good agreement; comparisons with other analysis systems yielded in several cases explicable deviations. Practicability of Cobas Integra 800 met or exceeded the requirements for more than 95% of all attributes rated. The strong points of the new analysis system were reagent handling, long stability of calibration curves, high number of tests on board, compatibility of the sample carrier to other Roche systems, and the sample integrity check for more reliable analytical results. The improvement of the workflow offered by the 5-position rack and STAT handling like on Cobas Integra 800 makes the instrument attractive for further consolidation in the medium-sized laboratory, for dedicated use of special analytes, and/or as back-up in the large routine laboratory.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1434-6621
1437-4331
DOI:10.1515/CCLM.2003.058