Calculating Parameters of Pinhole in Collimation System of Albedo Computed Tomography of Steel Products

We examine specific features of the collimation system of a tomograph for testing steel products based on Compton backscattering. The device is described and the parameters of the primary pinhole collimator of the collimation system are calculated. The device allows reliable scanning of a steel test...

Full description

Saved in:
Bibliographic Details
Published inRussian journal of nondestructive testing Vol. 56; no. 2; pp. 171 - 178
Main Authors Zhuravskii, E. E., Kapranov, B. I., Belkin, D. S., Chakhlov, S. V., Shtein, A. M.
Format Journal Article
LanguageEnglish
Published Moscow Pleiades Publishing 01.02.2020
Springer Nature B.V
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:We examine specific features of the collimation system of a tomograph for testing steel products based on Compton backscattering. The device is described and the parameters of the primary pinhole collimator of the collimation system are calculated. The device allows reliable scanning of a steel test object by simply displacing the pinhole perpendicular to the X-ray axis from the tube anode within 50 mm with a focal length of 163 mm.
ISSN:1061-8309
1608-3385
DOI:10.1134/S1061830920020102