Determination of gallic acid using poly(glutamic acid): graphene modified electrode
Gallic acid (GA) is one of the main phenolic components occurring naturally in plants and has been a subject of increasing interest owing to its antioxidant, anti-mutagenic and anti-carcinogenic properties. The present work describes a rapid and cost-effective analytical procedure for the determinat...
Saved in:
Published in | Journal of chemical sciences (Bangalore, India) Vol. 131; no. 2; pp. 1 - 10 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
New Delhi
Springer India
01.02.2019
Springer Nature B.V |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Gallic acid (GA) is one of the main phenolic components occurring naturally in plants and has been a subject of increasing interest owing to its antioxidant, anti-mutagenic and anti-carcinogenic properties. The present work describes a rapid and cost-effective analytical procedure for the determination of gallic acid. Poly-Glu/rGO electrode was fabricated by the electro-polymerisation of glutamic acid on reduced graphene oxide (rGO) modified paraffin impregnated graphite electrode (PIGE). The modified electrode was characterized by SEM, AFM and ATR-IR. The electrochemical behavior of gallic acid at the modified sensor was studied by voltammetric and amperometric techniques under optimized conditions in pH 5 acetate buffer. The electrode showed good linear response towards the determination of gallic acid over the range of 0.03–480
μ
M
with 0.01
μ
M
as the detection limit for voltammetric technique and the amperometric technique showed a linear range of 1–17
μ
M
with 0.33
μ
M
as the detection limit. The electrode also showed good stability and reproducibility with a sensitivity of 0.97
μ
M
/
μ
A. The proposed method can be applied to detect GA in real samples with satisfactory results.
Graphical abstract
SYNOPSIS
This work describes a rapid and cost-effective analytical procedure for the determination of gallic acid. Poly-Glu/rGO electrode was fabricated by electro-polymerisation of glutamic acid on reduced graphene oxide (rGO) modified paraffin impregnated graphite electrode (PIGE). The electrode showed linear response towards gallic acid over the range of 0.03–480
μ
M
with 0.01
μ
M
as the detection limit for voltammetric technique and a linear range of 1–17
μ
M
with 0.33
μ
M
as the detection limit for amperometric technique. The proposed electrochemical sensor can be applied to detect GA in real samples with satisfactory results. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 |