Effect of plume dynamics on surface contamination during interaction of millisecond infrared fiber laser with titanium

•Influence of plume dynamics on surface contamination during interaction of laser with titanium investigated by high-speed imaging and optical emission spectroscopy.•Reabsorption of the laser pulse by neutral titanium atoms in the plume results in dark colouration around the laser spot on the weld s...

Full description

Saved in:
Bibliographic Details
Published inOptics and lasers in engineering Vol. 153; p. 106996
Main Authors Mohanta, Antaryami, Leistner, Matthias, Leparoux, Marc
Format Journal Article
LanguageEnglish
Published Elsevier Ltd 01.06.2022
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:•Influence of plume dynamics on surface contamination during interaction of laser with titanium investigated by high-speed imaging and optical emission spectroscopy.•Reabsorption of the laser pulse by neutral titanium atoms in the plume results in dark colouration around the laser spot on the weld surface.•Effect of ambient gas atmospheres, pressures, laser's spectral profiles, powers and pulse durations on plume dynamics and surface contamination.•Clean weld appearance for laser with customized spectral profile, which does not overlap with neutral atomic titanium transitions. Dynamics of the plume produced due to the interaction of millisecond infrared fiber lasers having different spectral profiles with titanium is investigated by high-speed imaging (HSI) and optical emission spectroscopy (OES) at different ambient atmospheres and pressures. The surface quality is associated with different plume dynamics that depends on the processing conditions. Reabsorption of the laser pulse by the neutral titanium atoms due to overlap of laser spectral profile with corresponding transition energies causes deposition of nanoparticles on the surface around the spot produced by the laser, which results in surface contamination and darkness around the spot. Increasing confinement of plume in Ar ambient than Ar/He leads to more darkness around the spot due to more availability of Ti species in a smaller volume for reabsorption. In vacuum/at low pressures, larger size of the expanding plume causes a smaller number of Ti species to interact with the laser pulse that produces clean surface around the spot. The surface contamination is prevented irrespective of the processing conditions by using the laser with customized spectral profile, which does not overlap with any neutral titanium atomic transitions (Ti I).
ISSN:0143-8166
1873-0302