Electron temperature diagnostics of aluminium plasma in a z-pinch experiment at the "QiangGuang-1" facility

Two curved crystal spectrometers are set up on the "QiangGuang-1" generator to measure the z-pinch plasma spectra emitted from planar aluminum wire array loads. Kodak Biomax-MS film and an IRD AXUVHS5# array are employed to record time-integrated and time-resolved free-bound radiation, respectively....

Full description

Saved in:
Bibliographic Details
Published inChinese physics B Vol. 21; no. 12; pp. 322 - 326
Main Author 李沫 吴坚 王亮平 吴刚 韩娟娟 郭宁 邱孟通
Format Journal Article
LanguageEnglish
Published 01.12.2012
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Two curved crystal spectrometers are set up on the "QiangGuang-1" generator to measure the z-pinch plasma spectra emitted from planar aluminum wire array loads. Kodak Biomax-MS film and an IRD AXUVHS5# array are employed to record time-integrated and time-resolved free-bound radiation, respectively. The photon energy recorded by each detector is ascertained by using the L-shell lines of molybdenum plasma. Based on the exponential relation between the continuum power and photon energies, the aluminum plasma electron temperatures are measured. For the time-integrated diagnosis, several "bright spots" indicate electron temperatures between (450 eV- 520 eV) ± 35%. And for the time-resolved ones, the result shows that the electron temperature reaches about 800 eV±30% at peak power. The system satisfies the demand of z-pinch plasma electron temperature diagnosis on a - 1 MA facility.
Bibliography:Li Mo, Wu Jian, Wang Liang-Ping, Wu Gang, Man Juan-Juan Guo Ning, and Qiu Meng-TongNorthwest Institute of Nuclear Technology, Xi'an 710024, China
electron temperature, continuum, curved crystal spectrometer, z-pinch
11-5639/O4
Two curved crystal spectrometers are set up on the "QiangGuang-1" generator to measure the z-pinch plasma spectra emitted from planar aluminum wire array loads. Kodak Biomax-MS film and an IRD AXUVHS5# array are employed to record time-integrated and time-resolved free-bound radiation, respectively. The photon energy recorded by each detector is ascertained by using the L-shell lines of molybdenum plasma. Based on the exponential relation between the continuum power and photon energies, the aluminum plasma electron temperatures are measured. For the time-integrated diagnosis, several "bright spots" indicate electron temperatures between (450 eV- 520 eV) ± 35%. And for the time-resolved ones, the result shows that the electron temperature reaches about 800 eV±30% at peak power. The system satisfies the demand of z-pinch plasma electron temperature diagnosis on a - 1 MA facility.
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1674-1056
2058-3834
1741-4199
DOI:10.1088/1674-1056/21/12/125202