Electron temperature diagnostics of aluminium plasma in a z-pinch experiment at the "QiangGuang-1" facility
Two curved crystal spectrometers are set up on the "QiangGuang-1" generator to measure the z-pinch plasma spectra emitted from planar aluminum wire array loads. Kodak Biomax-MS film and an IRD AXUVHS5# array are employed to record time-integrated and time-resolved free-bound radiation, respectively....
Saved in:
Published in | Chinese physics B Vol. 21; no. 12; pp. 322 - 326 |
---|---|
Main Author | |
Format | Journal Article |
Language | English |
Published |
01.12.2012
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Two curved crystal spectrometers are set up on the "QiangGuang-1" generator to measure the z-pinch plasma spectra emitted from planar aluminum wire array loads. Kodak Biomax-MS film and an IRD AXUVHS5# array are employed to record time-integrated and time-resolved free-bound radiation, respectively. The photon energy recorded by each detector is ascertained by using the L-shell lines of molybdenum plasma. Based on the exponential relation between the continuum power and photon energies, the aluminum plasma electron temperatures are measured. For the time-integrated diagnosis, several "bright spots" indicate electron temperatures between (450 eV- 520 eV) ± 35%. And for the time-resolved ones, the result shows that the electron temperature reaches about 800 eV±30% at peak power. The system satisfies the demand of z-pinch plasma electron temperature diagnosis on a - 1 MA facility. |
---|---|
Bibliography: | Li Mo, Wu Jian, Wang Liang-Ping, Wu Gang, Man Juan-Juan Guo Ning, and Qiu Meng-TongNorthwest Institute of Nuclear Technology, Xi'an 710024, China electron temperature, continuum, curved crystal spectrometer, z-pinch 11-5639/O4 Two curved crystal spectrometers are set up on the "QiangGuang-1" generator to measure the z-pinch plasma spectra emitted from planar aluminum wire array loads. Kodak Biomax-MS film and an IRD AXUVHS5# array are employed to record time-integrated and time-resolved free-bound radiation, respectively. The photon energy recorded by each detector is ascertained by using the L-shell lines of molybdenum plasma. Based on the exponential relation between the continuum power and photon energies, the aluminum plasma electron temperatures are measured. For the time-integrated diagnosis, several "bright spots" indicate electron temperatures between (450 eV- 520 eV) ± 35%. And for the time-resolved ones, the result shows that the electron temperature reaches about 800 eV±30% at peak power. The system satisfies the demand of z-pinch plasma electron temperature diagnosis on a - 1 MA facility. ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 1674-1056 2058-3834 1741-4199 |
DOI: | 10.1088/1674-1056/21/12/125202 |