Wavelength modulation spectroscopy at 1530.32 nm for measurements of acetylene based on Fabry-Perot tunable filter

Sensitive detection of acetylene(C_2H_2) is performed by absorption spectroscopy and wavelength modulation spectroscopy(WMS) based on Fiber Fabry–Perot tunable filter(FFP-TF) at 1530.32 nm. After being calibrated by Fiber Bragg Grating(FBG), FFP-TF is frequency-multiplexed and modulated at 20 Hz and...

Full description

Saved in:
Bibliographic Details
Published inChinese physics B Vol. 25; no. 2; pp. 200 - 204
Main Author 李运龙 杨兵初 许雪梅
Format Journal Article
LanguageEnglish
Published 01.02.2016
Subjects
Online AccessGet full text
ISSN1674-1056
2058-3834
1741-4199
DOI10.1088/1674-1056/25/2/024208

Cover

More Information
Summary:Sensitive detection of acetylene(C_2H_2) is performed by absorption spectroscopy and wavelength modulation spectroscopy(WMS) based on Fiber Fabry–Perot tunable filter(FFP-TF) at 1530.32 nm. After being calibrated by Fiber Bragg Grating(FBG), FFP-TF is frequency-multiplexed and modulated at 20 Hz and 2.5 kHz respectively to achieve wavelength modulation. The linearity with 0.9907 fitting coefficient is obtained by measuring different concentrations in a 100 ppmv–400 ppmv range. Furthermore, the stability of the system is analyzed by detecting 50 ppmv and 100 ppmv standard gases for 2 h under room temperature and ambient pressure conditions respectively. The precision of 11 ppmv is achieved by calculating the standard deviation. Therefore, the measuring system of C_2H_2 detection can be applied in practical applications.
Bibliography:absorption spectroscopy, Fabry-Perot tunable filter, wavelength modulation, acetylene detection
Sensitive detection of acetylene(C_2H_2) is performed by absorption spectroscopy and wavelength modulation spectroscopy(WMS) based on Fiber Fabry–Perot tunable filter(FFP-TF) at 1530.32 nm. After being calibrated by Fiber Bragg Grating(FBG), FFP-TF is frequency-multiplexed and modulated at 20 Hz and 2.5 kHz respectively to achieve wavelength modulation. The linearity with 0.9907 fitting coefficient is obtained by measuring different concentrations in a 100 ppmv–400 ppmv range. Furthermore, the stability of the system is analyzed by detecting 50 ppmv and 100 ppmv standard gases for 2 h under room temperature and ambient pressure conditions respectively. The precision of 11 ppmv is achieved by calculating the standard deviation. Therefore, the measuring system of C_2H_2 detection can be applied in practical applications.
Yun-Long Li, Bing-Chu Yang, and Xue-Mei Xu(1 School of Physics and Electronics, Central South University, Changsha 410083, China)
11-5639/O4
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1674-1056
2058-3834
1741-4199
DOI:10.1088/1674-1056/25/2/024208