Wavelength modulation spectroscopy at 1530.32 nm for measurements of acetylene based on Fabry-Perot tunable filter
Sensitive detection of acetylene(C_2H_2) is performed by absorption spectroscopy and wavelength modulation spectroscopy(WMS) based on Fiber Fabry–Perot tunable filter(FFP-TF) at 1530.32 nm. After being calibrated by Fiber Bragg Grating(FBG), FFP-TF is frequency-multiplexed and modulated at 20 Hz and...
Saved in:
Published in | Chinese physics B Vol. 25; no. 2; pp. 200 - 204 |
---|---|
Main Author | |
Format | Journal Article |
Language | English |
Published |
01.02.2016
|
Subjects | |
Online Access | Get full text |
ISSN | 1674-1056 2058-3834 1741-4199 |
DOI | 10.1088/1674-1056/25/2/024208 |
Cover
Summary: | Sensitive detection of acetylene(C_2H_2) is performed by absorption spectroscopy and wavelength modulation spectroscopy(WMS) based on Fiber Fabry–Perot tunable filter(FFP-TF) at 1530.32 nm. After being calibrated by Fiber Bragg Grating(FBG), FFP-TF is frequency-multiplexed and modulated at 20 Hz and 2.5 kHz respectively to achieve wavelength modulation. The linearity with 0.9907 fitting coefficient is obtained by measuring different concentrations in a 100 ppmv–400 ppmv range. Furthermore, the stability of the system is analyzed by detecting 50 ppmv and 100 ppmv standard gases for 2 h under room temperature and ambient pressure conditions respectively. The precision of 11 ppmv is achieved by calculating the standard deviation. Therefore, the measuring system of C_2H_2 detection can be applied in practical applications. |
---|---|
Bibliography: | absorption spectroscopy, Fabry-Perot tunable filter, wavelength modulation, acetylene detection Sensitive detection of acetylene(C_2H_2) is performed by absorption spectroscopy and wavelength modulation spectroscopy(WMS) based on Fiber Fabry–Perot tunable filter(FFP-TF) at 1530.32 nm. After being calibrated by Fiber Bragg Grating(FBG), FFP-TF is frequency-multiplexed and modulated at 20 Hz and 2.5 kHz respectively to achieve wavelength modulation. The linearity with 0.9907 fitting coefficient is obtained by measuring different concentrations in a 100 ppmv–400 ppmv range. Furthermore, the stability of the system is analyzed by detecting 50 ppmv and 100 ppmv standard gases for 2 h under room temperature and ambient pressure conditions respectively. The precision of 11 ppmv is achieved by calculating the standard deviation. Therefore, the measuring system of C_2H_2 detection can be applied in practical applications. Yun-Long Li, Bing-Chu Yang, and Xue-Mei Xu(1 School of Physics and Electronics, Central South University, Changsha 410083, China) 11-5639/O4 ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 1674-1056 2058-3834 1741-4199 |
DOI: | 10.1088/1674-1056/25/2/024208 |