Study of the optimal duty cycle and pumping rate for square-wave amplitude-modulated Bell–Bloom magnetometers

We theoretically and experimentally study the optimal duty cycle and pumping rate for square-wave amplitudemodulated Bell–Bloom magnetometers.The theoretical and the experimental results are in good agreement for duty cycles and corresponding pumping rates ranging over 2 orders of magnitude.Our stud...

Full description

Saved in:
Bibliographic Details
Published inChinese physics B Vol. 25; no. 6; pp. 144 - 149
Main Author 王美玲 王梦冰 张桂迎 赵凯锋
Format Journal Article
LanguageEnglish
Published 01.06.2016
Subjects
Online AccessGet full text
ISSN1674-1056
2058-3834
1741-4199
DOI10.1088/1674-1056/25/6/060701

Cover

More Information
Summary:We theoretically and experimentally study the optimal duty cycle and pumping rate for square-wave amplitudemodulated Bell–Bloom magnetometers.The theoretical and the experimental results are in good agreement for duty cycles and corresponding pumping rates ranging over 2 orders of magnitude.Our study gives the maximum field response as a function of duty cycle and pumping rate.Especially,for a fixed duty cycle,the maximum field response is obtained when the time averaged pumping rate,which is the product of pumping rate and duty cycle,is equal to the transverse relaxation rate in the dark.By using a combination of small duty cycle and large pumping rate,one can increase the maximum field response by up to a factor of 2 or π /2,relative to that of the sinusoidal modulation or the 50% duty cycle square-wave modulation respectively.We further show that the same pumping condition is also practically optimal for the sensitivity due to the fact that the signal at resonance is insensitive to the fluctuations of pumping rate and duty cycle.
Bibliography:Mei-Ling Wang,Meng-Bing Wang,Gui-Ying Zhang,Kai-Feng Zhao
We theoretically and experimentally study the optimal duty cycle and pumping rate for square-wave amplitudemodulated Bell–Bloom magnetometers.The theoretical and the experimental results are in good agreement for duty cycles and corresponding pumping rates ranging over 2 orders of magnitude.Our study gives the maximum field response as a function of duty cycle and pumping rate.Especially,for a fixed duty cycle,the maximum field response is obtained when the time averaged pumping rate,which is the product of pumping rate and duty cycle,is equal to the transverse relaxation rate in the dark.By using a combination of small duty cycle and large pumping rate,one can increase the maximum field response by up to a factor of 2 or π /2,relative to that of the sinusoidal modulation or the 50% duty cycle square-wave modulation respectively.We further show that the same pumping condition is also practically optimal for the sensitivity due to the fact that the signal at resonance is insensitive to the fluctuations of pumping rate and duty cycle.
11-5639/O4
optical pumping;spin relaxation;power-broadening;magnetometry
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1674-1056
2058-3834
1741-4199
DOI:10.1088/1674-1056/25/6/060701