Combining conventional technique with fluoroscopy integration module in accessory pathway ablation

Introduction Accessory pathway (AP) ablation is a straightforward approach with high success rates, but the fluoroscopy time (FT) is significantly longer in conventional technique. Electroanatomical mapping systems (EMS), reduce the FT, but anatomical and activation mapping may prolong the procedure...

Full description

Saved in:
Bibliographic Details
Published inJournal of cardiovascular electrophysiology Vol. 34; no. 12; pp. 2573 - 2580
Main Authors Ozcan, Emin Evren, Turan, Oğuzhan Ekrem, Yilancioğlu, Reşit Yiğit, Inevi, Umut, Akdemir, Barış
Format Journal Article
LanguageEnglish
Published United States Wiley Subscription Services, Inc 01.12.2023
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Introduction Accessory pathway (AP) ablation is a straightforward approach with high success rates, but the fluoroscopy time (FT) is significantly longer in conventional technique. Electroanatomical mapping systems (EMS), reduce the FT, but anatomical and activation mapping may prolong the procedure time (PT). The fluoroscopy integration module (FIM) uses prerecorded fluoroscopy images and allows ablation similar to conventional technique without creating an anatomical map. In this study, we investigated the effects of combining the FIM with traditional technique on PT, success, and radiation exposure. Methods A total of 131 patients who had undergone AP ablation were included in our study. In 37 patients, right and left anterior oblique (RAO‐LAO) images were acquired after catheter placement and integrated with the FIM. The ablation procedure was then similar to the conventional technique, but without the use of fluoroscopy. For the purpose of acceleration, anatomical and activation maps have not been created. Contact‐force catheters were not used. 94 patients underwent conventional ablation using fluoroscopy only. Results FIM into AP ablation procedures led to a significant reduction in radiation exposure, lowering FT from 7.4 to 2.8 min (p < .001) and dose‐area product from 12.47 to 5.8 μGym² (p < .001). While the FIM group experienced a reasonable longer PT (69 vs. 50 min p < .001). FIM reduces FT regardless of operator experience and location of APs Conclusion Combining FIM integration with conventional AP ablation offers reduced radiation exposure without compromising success rates and complication. Fluoroscopy integration module (FIM) facilitates 3D guided accessory pathway ablation without anatomical reconstruction. Combining conventional technique with FIM provide significantly reduced radiation exposure with reasonable procedure time.  FIM, fluoroscopy integration module; 3D, 3 dimensional.
Bibliography:Disclosures
None.
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1045-3873
1540-8167
1540-8167
DOI:10.1111/jce.16110