Development and Validation of Facile RP-HPLC Method for Simultaneous Determination of Timolol Maleate, Moxifloxacin Hydrochloride, Diclofenac Sodium and Dexamethasone in Plasma, Aqueous Humor and Pharmaceutical Products

Abstract The present study aimed to develop a validated RP-HPLC method for the simultaneous determination of timolol maleate (TM), moxifloxacin hydrochloride (MOXI), diclofenac sodium (DS) and dexamethasone (DEXA) in human plasma, bovine aqueous humor and pharmaceutical preparations. The chromatogra...

Full description

Saved in:
Bibliographic Details
Published inJournal of chromatographic science Vol. 61; no. 7; pp. 678 - 687
Main Authors Shahzad, Aqeel, Arshad, Sohail, Zubair, Faryal, Shahzad, Shakeel, Batool, Farzana, Fu, Qiang
Format Journal Article
LanguageEnglish
Published Oxford University Press 19.08.2023
Online AccessGet full text

Cover

Loading…
More Information
Summary:Abstract The present study aimed to develop a validated RP-HPLC method for the simultaneous determination of timolol maleate (TM), moxifloxacin hydrochloride (MOXI), diclofenac sodium (DS) and dexamethasone (DEXA) in human plasma, bovine aqueous humor and pharmaceutical preparations. The chromatographic separation was studied using the C18 column. The chromatographic conditions, such as composition, pH, the flow rate of mobile phase, the temperature of column, wavelength of absorption and injection volume of the sample, were studied. The method was validated to confirm specificity, linearity and accuracy in accordance with an International Conference on Harmonization guidelines. The optimum conditions for separation included mobile phase 0.05 M monobasic phosphate buffer: acetonitrile (65:35 v/v), pH of buffer adjusted to 6.2 and the flow rate of 1 mL/minute. The optimum temperature of the column was found to be 35°C, absorption wavelength 265 nm and injection volume 50 μL. The baseline separation of all four drugs with good sensitivity, resolution, and a less than 15 min run time was achieved. The retention time of TM, MOXI, DS and DEXA were 4.3,5.7,9.9 and 13.5 minutes respectively. The limit of detection (LOD) values were 6.2, 4.8, 0.8 and 1.2 ng/mL for TM, MOXI, DS and DEXA, respectively, whereas their respective limit of quantification (LOQ) values was: were 42.6, 26.8, 5.6 and 6.2 ng/mL. The coefficient of variation for intra-day and inter-day were in the range of 0.32–1.57 and 1.29–3.07%, respectively. The method was found to be sensitive, precise and accurate in human plasma and bovine aqueous humor and can be applied for the quantification of these compounds in plasma, aqueous humor and pharmaceuticals.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0021-9665
1945-239X
DOI:10.1093/chromsci/bmac057