Dampness in dorm rooms and its associations with allergy and airways infections among college students in China: a cross-sectional study
A cross-sectional study was carried out at Tianjin University campus, China, from February 21 to June 10, 2006, to survey the association between dampness in dorms, and allergy and airways infections among college students. The health and dampness conditions were self-reported by 3436 students livin...
Saved in:
Published in | Indoor air Vol. 19; no. 4; pp. 348 - 356 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English |
Published |
Oxford, UK
Blackwell Publishing Ltd
01.08.2009
|
Subjects | |
Online Access | Get full text |
ISSN | 0905-6947 1600-0668 1600-0668 |
DOI | 10.1111/j.1600-0668.2009.00614.x |
Cover
Loading…
Summary: | A cross-sectional study was carried out at Tianjin University campus, China, from February 21 to June 10, 2006, to survey the association between dampness in dorms, and allergy and airways infections among college students. The health and dampness conditions were self-reported by 3436 students living in 1511 dorm rooms located in 13 buildings on the campus. The buildings were selected according to their positions, construction periods and occupant densities. The symptoms involved wheezing, dry cough during night, rhinitis, eczema, cold/flu, ear inflammation, pneumonia and tuberculosis. The indoor moisture signs were mould/damp spots on walls, ceilings and floors; suspected or ever happened water damage; condensation on windowpane in winter and odours perceived by subjects themselves. There was a significant positive association between condensation and dry cough. Eczema was often reported in rooms with moisture problem. Dampness was a significant risk factor for common cold.
Dampness problems in dorms of Chinese students are a risk factor for allergic symptoms, and hence there is a need for dorm environment improvement. Health problems related to ventilation and microbiology problems in dorms should be further studied. |
---|---|
Bibliography: | istex:8CA9C13A2E532170D073709D65F68960533E3338 ark:/67375/WNG-QX8CRR02-K ArticleID:INA614 19 , This erratum is published to replace in full Sun, Y., Zhang, Y., Sundell, J., Fan, Z., and Bao, L. (2009) Dampness at dorm and its associations with allergy and airways infection among college students in China: a cross‐sectional study 174–182. Indoor Air ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Feature-1 content type line 23 ObjectType-Article-1 ObjectType-Feature-2 |
ISSN: | 0905-6947 1600-0668 1600-0668 |
DOI: | 10.1111/j.1600-0668.2009.00614.x |