Impact of Post-Intervention Minimal Stent Area on 9-Month Follow-Up Patency of Paclitaxel-Eluting Stents
Objectives We investigated the predictive value of the intravascular ultrasound (IVUS) measured post-intervention minimum stent area (MSA) on 9-month follow-up paclitaxel-eluting stent (PES) patency compared with bare-metal stents (BMS). Background Stent underexpansion is a strong predictor for rest...
Saved in:
Published in | JACC. Cardiovascular interventions Vol. 2; no. 12; pp. 1269 - 1275 |
---|---|
Main Authors | , , , , , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
Elsevier Inc
01.12.2009
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Objectives We investigated the predictive value of the intravascular ultrasound (IVUS) measured post-intervention minimum stent area (MSA) on 9-month follow-up paclitaxel-eluting stent (PES) patency compared with bare-metal stents (BMS). Background Stent underexpansion is a strong predictor for restenosis after sirolimus-eluting stent implantation, but the implication of underexpansion in PES is still unknown. Methods From the combined TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent trials, 1,580 patients (PES 1,098, BMS 482) in IVUS substudies were analyzed. The MSA that best predicted angiographic in-stent restenosis (ISR) (% diameter stenosis ≥50%) was determined. Results The post-intervention IVUS MSA was similar in PES and BMS (6.6 ± 2.5 mm2 vs. 6.7 ± 2.3 mm2 , p = 0.92). At 9-month follow-up, ISR was lower in the PES group versus the BMS group (10% vs. 31%, p < 0.0001). Using multivariable logistic regression analysis, post-intervention IVUS MSA was the independent predictor of subsequent ISR in both the PES and BMS groups (p = 0.0002 for PES and p = 0.0002 for BMS). The ability of the post-intervention IVUS MSA to predict ISR was further assessed using receiver operating characteristic analysis. The post-intervention IVUS MSA was found to be a faithful discriminator between patients with and without ISR in both PES (c = 0.6382) and BMS (c = 0.6373). Finally, the optimal thresholds of post-intervention IVUS MSA that best predicted stent patency at 9 months were 5.7 mm2 for PES and 6.4 mm2 for BMS. Conclusions Post-intervention MSA measured by IVUS can predict 9-month follow-up stent patency after both PES and BMS implantation. (Randomized Trial Evaluating Slow-Release Formulation TAXUS Paclitaxel-Eluting Coronary Stents to Treat De Novo Coronary Lesions; NCT00301522 ) (Direct Stenting of TAXUS Liberté-SR Stent for the Treatment of Patients With de Novo Coronary Artery Lesions; NCT00371423 ) (A Study of the TAXUS Liberté Stent for the Treatment of Long De Novo Coronary Artery Lesions; NCT00371475 ) (A Study of the TAXUS Liberté Stent for the Treatment of de Novo Coronary Artery Lesions in Small Vessels; NCT00371748 ) |
---|---|
ISSN: | 1936-8798 1876-7605 |
DOI: | 10.1016/j.jcin.2009.10.005 |