Radiolabeling Methods

In vivo measurements of the deposition of an inhaled radiolabeled pharmaceutic have provided useful information related to the inhaler efficiency for depositing drug in the lung. A number of labeling techniques have been developed and applied to pharmaceutical aerosols delivered by pressurized meter...

Full description

Saved in:
Bibliographic Details
Published inJournal of aerosol medicine and pulmonary drug delivery Vol. 35; no. 4; pp. 227 - 236
Main Author Dolovich, Myrna B.
Format Journal Article
LanguageEnglish
Published 01.08.2022
Online AccessGet full text

Cover

Loading…
More Information
Summary:In vivo measurements of the deposition of an inhaled radiolabeled pharmaceutic have provided useful information related to the inhaler efficiency for depositing drug in the lung. A number of labeling techniques have been developed and applied to pharmaceutical aerosols delivered by pressurized metered-dose inhalers (pMDIs), dry powder inhalers (DPIs) and nebulizers; the choice of radiotracer depends on the type of imaging study being performed and the equipment used to image the lung. Preparation, validation and calibration of the radiolabeled pharmaceutical product is key to successful interpretation of the imaging study. When imaging a subject after inhalation of a radiolabeled formulation, it is the radioactivity that is detected and measured by the scanner; absolute amounts of deposited drug are inferred from the counts of radioactivity in the lung and other regions, based on the assumption that there is a 1:1 relationship between the two components-drug and radioactivity. This relationship holds true for direct-labeled PET products or for those formulations where a firm bond can be demonstrated between the drug and radiotracer for the time taken to acquire all the images. This chapter will discuss radiolabeling methods applied to therapeutic aerosols for the purpose of determining the deposition efficiency of these aerosols in the lung. The techniques apply to both in vivo studies in man and in animal models, and to some extent to in vitro models.In vivo measurements of the deposition of an inhaled radiolabeled pharmaceutic have provided useful information related to the inhaler efficiency for depositing drug in the lung. A number of labeling techniques have been developed and applied to pharmaceutical aerosols delivered by pressurized metered-dose inhalers (pMDIs), dry powder inhalers (DPIs) and nebulizers; the choice of radiotracer depends on the type of imaging study being performed and the equipment used to image the lung. Preparation, validation and calibration of the radiolabeled pharmaceutical product is key to successful interpretation of the imaging study. When imaging a subject after inhalation of a radiolabeled formulation, it is the radioactivity that is detected and measured by the scanner; absolute amounts of deposited drug are inferred from the counts of radioactivity in the lung and other regions, based on the assumption that there is a 1:1 relationship between the two components-drug and radioactivity. This relationship holds true for direct-labeled PET products or for those formulations where a firm bond can be demonstrated between the drug and radiotracer for the time taken to acquire all the images. This chapter will discuss radiolabeling methods applied to therapeutic aerosols for the purpose of determining the deposition efficiency of these aerosols in the lung. The techniques apply to both in vivo studies in man and in animal models, and to some extent to in vitro models.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
ObjectType-Review-3
content type line 23
ISSN:1941-2711
1941-2703
1941-2703
DOI:10.1089/jamp.2022.29067.md