Surface analysis of biocompatible coatings on titanium
The coatings of hydroxyapatite, which is widely used for orthopaedic and dental prothesis, were deposited by using the dip-coating method. The layers of hydroxyapatite were grown on commercial Ti substrates. In order to improve the adhesion of hydroxyapatite, the substrate was a priori covered with...
Saved in:
Published in | Journal of electron spectroscopy and related phenomena Vol. 95; no. 1; pp. 61 - 69 |
---|---|
Main Authors | , , , , , , |
Format | Journal Article |
Language | English |
Published |
Elsevier B.V
01.08.1998
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | The coatings of hydroxyapatite, which is widely used for orthopaedic and dental prothesis, were deposited by using the dip-coating method. The layers of hydroxyapatite were grown on commercial Ti substrates. In order to improve the adhesion of hydroxyapatite, the substrate was a priori covered with titania or calcium titanate by using the sol-gel technique. For comparison, commercial samples of hydroxyapatite coating (manufactured by means of plasma-spray apparatus) were analysed. The chemical composition and the structure of the coatings (TiO
2, CaTiO
3 and hydroxyapatite) were studied by using X-ray photoelectron spectroscopy (XPS), scanning Auger microscopy (SAM), X-ray diffraction (XRD) and secondary electron microscopy (SEM) techniques. The data of quantitative XPS analysis and the surface images (SAM and SEM) displayed the superior quality (cleanness, homogeneity, etc.) of hydroxyapatite deposited by sol-gel in comparison with commercial samples investigated. |
---|---|
ISSN: | 0368-2048 1873-2526 |
DOI: | 10.1016/S0368-2048(98)00202-3 |