Real-Time Dynamic Spectrum Analysis for Plasma Electron Density and Faraday Rotation Angle Measurement on HL-2A

Electron density and Faraday rotation angle are important physical parameters in nuclear fusion research.To measure them simultaneously,the three-wave polarimeter/interferometer diagnostic system is applied.Both the final probe output signal and the reference signal contain three frequency component...

Full description

Saved in:
Bibliographic Details
Published inPlasma science & technology Vol. 17; no. 12; pp. 1092 - 1096
Main Author 丁宝钢 吴军 范伟伟 吴彤宇 周艳 阴泽杰
Format Journal Article
LanguageEnglish
Published 01.12.2015
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Electron density and Faraday rotation angle are important physical parameters in nuclear fusion research.To measure them simultaneously,the three-wave polarimeter/interferometer diagnostic system is applied.Both the final probe output signal and the reference signal contain three frequency components.The time-varying phase difference curve of each frequency component can be measured by the Real-time Dynamic Spectrum Analysis(RDSA)method based on Field-Programmable Gate Array(FPGA).The phase difference precision is better than 0.1° and the real-time feedback delay is less than 1 ms,which satisfy the requirements of HL-2A.
Bibliography:Electron Spectrum Faraday rotation interferometer satisfy performing Angle instead rotating
DING Baogang , WU Jun , FAN Weiwei , WU Tongyu , ZHOU Yan, YIN Zejie( 1State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei 230026, China ;2Department of Modern Physics, University of Science and Technology of China, Hefei 230026, China ;3Southwestern Institute of Physics, Chengdu 610041, China ;4Shanghai Radio Equipment Institute, Shanghai 200090, China)
Electron density and Faraday rotation angle are important physical parameters in nuclear fusion research.To measure them simultaneously,the three-wave polarimeter/interferometer diagnostic system is applied.Both the final probe output signal and the reference signal contain three frequency components.The time-varying phase difference curve of each frequency component can be measured by the Real-time Dynamic Spectrum Analysis(RDSA)method based on Field-Programmable Gate Array(FPGA).The phase difference precision is better than 0.1° and the real-time feedback delay is less than 1 ms,which satisfy the requirements of HL-2A.