Venous haemodynamics of Jet Impulse Technology within a lower limb fibreglass cast: a randomized controlled trial

Objectives We investigated popliteal venous haemodynamics of the VenaJet Jet Impulse Technology system within a below-knee fibreglass cast. Design Randomized controlled trial. Participants Twenty-four healthy participants aged 18–54 had both feet placed within the Jet Impulse Technology system and w...

Full description

Saved in:
Bibliographic Details
Published inJRSM open Vol. 8; no. 2; p. 2054270416681746
Main Authors Braithwaite, Irene, Mackintosh, Stephen, Buchanan, Samantha, Schwarzenlander, Kerstin, De Ruyter, Bernadette
Format Journal Article
LanguageEnglish
Published London, England SAGE Publications 01.02.2017
Sage Publications Ltd
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objectives We investigated popliteal venous haemodynamics of the VenaJet Jet Impulse Technology system within a below-knee fibreglass cast. Design Randomized controlled trial. Participants Twenty-four healthy participants aged 18–54 had both feet placed within the Jet Impulse Technology system and were randomised for one or other leg to be within a below-knee fibreglass cast. Setting Pacific Radiology, Lower Hutt, Wellington Main outcome measures The primary outcome variable was peak systolic velocity (cm/s) compared between legs with and without the cast at 60 min (after 10 min Jet Impulse Technology activation), using a mixed linear model and a non-inferiority bound of 4.8 cm/s. Secondary outcome variables were the difference in peak systolic velocity between the casted limb and the non-casted limb at baseline and 40 min after casting, and the difference in mean flow velocity (cm/s), vein diameter (mm), and total volume flow (L/min) between the casted limb and the non-casted limb at baseline, 40 and 60 min. Results The mean (standard deviation) peak systolic velocity was 4.6(1.5), 4.8(1.1), 28.8(16.1), and 4.3(1.2), 4.8(1.4) and 29.3(19.0) cm/s at baseline, 40 and 60 min in the casted and non-casted leg, respectively. The difference (95% confidence interval) between cast and no-cast at 60 min was −0.8 (−6.5 to 4.9) cm/s, P = 0.78. The peak systolic velocity, flow velocity and total volume flow at 40 min were not statistically significantly different from baseline for both casted and non-casted limb. Conclusion In healthy volunteers, the popliteal venous haemodynamics of the Jet Impulse Technology system was similar between the legs with and without a below-knee fibreglass cast. In-cast Jet Impulse Technology may provide a non-pharmacological option for venous thromboembolism prophylaxis for lower-limb cast-immobility.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2054-2704
2054-2704
DOI:10.1177/2054270416681746