Optimization of beam orientation and virtual organ delineation for lung IMRT

This study demonstrates the feasibility of the proposed intensity-modulated radiotherapy (IMRT) techniques for minimizing the dose to the lungs and organs at risk (OARs) for variations in the number of beams, the orientations of the beams, the virtual organ delineation (VOD) position, the VOD size a...

Full description

Saved in:
Bibliographic Details
Published inJournal of the Korean Physical Society Vol. 64; no. 7; pp. 1047 - 1054
Main Authors Chang, Kyung Hwan, Lee, Suk, Cao, Yuan Jie, Shim, Jang Bo, Lee, Ji Eun, Lee, Jung Ae, Yang, Dae Sik, Park, Young Je, Yoon, Won Sup, Kim, Chul Yong, Cho, Sam Ju, Lee, Sang Hoon, Kim, Woo Chul, Min, Chul Kee, Cho, Kwang Hwan, Huh, Hyun Do
Format Journal Article
LanguageEnglish
Published Seoul The Korean Physical Society 01.04.2014
한국물리학회
Subjects
Online AccessGet full text
ISSN0374-4884
1976-8524
DOI10.3938/jkps.64.1047

Cover

More Information
Summary:This study demonstrates the feasibility of the proposed intensity-modulated radiotherapy (IMRT) techniques for minimizing the dose to the lungs and organs at risk (OARs) for variations in the number of beams, the orientations of the beams, the virtual organ delineation (VOD) position, the VOD size and the dose constraints in order to optimize the treatment plan for lung cancer. We used 5, 7, 9 and 14 equiangularly-spaced beams and 7 and 9 non-equiangularly-spaced beams. We measured the volume of the lungs receiving at least 20 Gy and 25 Gy (V 20 and V 25 ) for variations in the orientations of the beams, the VOD position, and the size of the tumor and the contra-lateral lung. For the tumor and the contra-lateral lung, the V 20 and the V 25 values of 14 equiangularlyspaced ports were slightly lower than those of other equiangularly-spaced beam orientations. For non-equiangularly-spaced beam orientations, the lowest V 20 and V 25 values in the tumor and the contral-lateral lung were recorded in ports 7, and 9, respectively. For tumors of the lung, the average values of 7 non-equiangularly-spaced ports were lower than those for 14 equiangularly-spaced ports. The values of V 20 and V 25 for variations in the VOD size and the VOD position showed no significant differences for the lung tumor of patient 1 when the dose constraint of the VOD was 10, 25 and 30 Gy. For the lung tumor, the values of V20 and V25 for various VOD sizes and positions ranged from 15 to 37% in patient 2 and from 28 to 45% in patient 3. The values of V 20 and V 25 were within 7% for the contra-lateral lung of patient 1. For patient 2, the values of V 20 and V 25 ranged from 7 to 18%. For the contra-lateral lung of patient 3, the V 20 and V 25 values ranged from 12 to 25%. IMRT techniques with various VOD and beam orientations are important for determine in treatment plans.
Bibliography:G704-000411.2014.64.7.005
ISSN:0374-4884
1976-8524
DOI:10.3938/jkps.64.1047