Radiation dose during interventional cardiology procedures: portable C-arm vs. a new generation fluoroscopy system
Occupational exposure to ionizing radiation poses health risks for veterinary interventionalists. There are limited veterinary studies evaluating radiation dose in the cardiac catheterization laboratory. The purpose of this study was to report direct radiation dose exposure to patients during common...
Saved in:
Published in | Journal of veterinary cardiology Vol. 47; pp. 30 - 40 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | English |
Published |
Netherlands
Elsevier B.V
01.06.2023
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Occupational exposure to ionizing radiation poses health risks for veterinary interventionalists. There are limited veterinary studies evaluating radiation dose in the cardiac catheterization laboratory. The purpose of this study was to report direct radiation dose exposure to patients during common interventional cardiology procedures and compare these doses between two fluoroscopy units.
One hundred and fifty-four client-owned dogs.
Patient dose during procedures using a portable C-arm were retrospectively analyzed and compared to those performed in a contemporary interventional suite. Fluoroscopy equipment, procedure type, operator, patient weight, fluoroscopy time, dose area product, and air kerma were recorded and statistically modeled using univariable and multivariable linear regression to evaluate the effect of each factor.
Patient dose population (154 dogs), comprised 61 patent ductus arteriosus occlusions, 60 balloon pulmonary valvuloplasties, and 33 pacemaker implantations. Patient dose was significantly lower in the group utilizing a newer generation fluoroscopy unit vs. the group utilizing an older portable C-arm, positively correlated with patient weight, and highest during balloon pulmonary valvuloplasties compared to patent ductus arteriosus occlusions or pacemaker implantations (all P<0.010).
Newer fluoroscopy systems can be equipped with technologies that improve image quality while reducing patient dose and radiation exposure to interventional personnel.
We documented a significant reduction in patient radiation dose using a newer fluoroscopy system as compared to an older portable C-arm for interventional cardiology procedures in animals. Improved knowledge of patient radiation dose factors may promote better radiation safety protocols in veterinary interventional cardiology. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 1760-2734 1875-0834 |
DOI: | 10.1016/j.jvc.2023.03.005 |