Density Profile and Fluctuation Measurements by Microwave Reflectometry on EAST

A microwave reflectometry system operating in the V-band frequency with extraor- dinary mode polarization has been developed on the EAST tokamak. The reflectometry system, using a voltage-controlled oscillator (VCO) source driven by an arbitrary waveform generator with high temporal resolution, can...

Full description

Saved in:
Bibliographic Details
Published inPlasma science & technology Vol. 16; no. 4; pp. 311 - 315
Main Author 张寿彪 苛翔 凌必利 王嵎民 张涛 韩翔 刘子奚 布景亮 李建刚
Format Journal Article
LanguageEnglish
Published 01.04.2014
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:A microwave reflectometry system operating in the V-band frequency with extraor- dinary mode polarization has been developed on the EAST tokamak. The reflectometry system, using a voltage-controlled oscillator (VCO) source driven by an arbitrary waveform generator with high temporal resolution, can operate for the density profile measurement. The result of the bench test shows that the output frequency of the VCO has a linear dependence on time. The dispersion of reflectometry system is determined and reported in this paper. The evolution of a pedestal density profile during the L-H transition is observed by the reflectometry in H-mode discharges on EAST tokamak. A frequency synthesizer is used to replace the VCO as microwave source for density fluctuation measurements. The level of density fluctuation in the pedestal shows an abrupt decrease when the plasma enters into H-mode. A coherent mode with a frequency of about 100 kHz is observed and the mode frequency decreases gradually as the pedestal evolves.
Bibliography:34-1187/TL
A microwave reflectometry system operating in the V-band frequency with extraor- dinary mode polarization has been developed on the EAST tokamak. The reflectometry system, using a voltage-controlled oscillator (VCO) source driven by an arbitrary waveform generator with high temporal resolution, can operate for the density profile measurement. The result of the bench test shows that the output frequency of the VCO has a linear dependence on time. The dispersion of reflectometry system is determined and reported in this paper. The evolution of a pedestal density profile during the L-H transition is observed by the reflectometry in H-mode discharges on EAST tokamak. A frequency synthesizer is used to replace the VCO as microwave source for density fluctuation measurements. The level of density fluctuation in the pedestal shows an abrupt decrease when the plasma enters into H-mode. A coherent mode with a frequency of about 100 kHz is observed and the mode frequency decreases gradually as the pedestal evolves.
microwave reflectometry, pedestal, density fluctuation, EAST
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1009-0630
DOI:10.1088/1009-0630/16/4/02