Efficient Manganese Removal in Fast Contact Filters with Continuous Bed Rinsing

There is a need to implement high-efficiency solutions for groundwater treatment, especially in the context of manganese compounds removal. This study analyzed the impact of a water treatment plant modernization to a technology of fast contact filters with continuous bed rinsing. On the basis of bas...

Full description

Saved in:
Bibliographic Details
Published inJournal of Ecological Engineering Vol. 22; no. 6; pp. 50 - 54
Main Authors Nosek, Dawid, Cydzik-Kwiatkowska, Agnieszka, Kozicki, Paweł
Format Journal Article
LanguageEnglish
Published Polish Society of Ecological Engineering (PTIE) 01.06.2021
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:There is a need to implement high-efficiency solutions for groundwater treatment, especially in the context of manganese compounds removal. This study analyzed the impact of a water treatment plant modernization to a technology of fast contact filters with continuous bed rinsing. On the basis of basic indicators of water pollution, such as iron, manganese, turbidity, color, and nitrogen compounds, the raw water collected from the groundwater intake and the water treated after the filtration process were characterized. A comparison of the efficiency of water treatment installation before and after modernization indicated that there was a significant improvement in the quality of treated water, especially in terms of manganese removal.
ISSN:2299-8993
2299-8993
DOI:10.12911/22998993/137674