Finite Element Analysis of Glass Fiber Reinforced Plastic Hyperbolic Natural Draft Cooling Tower

Applicating the finite element analysis software Ansys to do finite element analysis of a glass fiber reinforced plastic hyperbolic natural draft cooling tower .Under the working condition of gravity and wind load, to contrast the two models of the presence or absence of abdominal rod displacement,...

Full description

Saved in:
Bibliographic Details
Published inApplied Mechanics and Materials Vol. 365-366; pp. 237 - 240
Main Authors Wu, Nian Peng, Meng, Chun Ling, Li, Yun Long, Zhang, Wen Hua
Format Journal Article
LanguageEnglish
Published Zurich Trans Tech Publications Ltd 01.08.2013
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Applicating the finite element analysis software Ansys to do finite element analysis of a glass fiber reinforced plastic hyperbolic natural draft cooling tower .Under the working condition of gravity and wind load, to contrast the two models of the presence or absence of abdominal rod displacement, stress and unit axial force, and check the stability of compressive bar, and structural optimization. Analysis results can provide reference for the structural design of hyperbolic cooling tower.
Bibliography:Selected, peer reviewed papers from the 2013 2nd International Conference on Machine Design and Manufacturing Engineering (ICMDME 2013), May 1-2, 2013, Jeju Island, South Korea
ISBN:9783037857816
3037857811
ISSN:1660-9336
1662-7482
1662-7482
DOI:10.4028/www.scientific.net/AMM.365-366.237