Mixed venous oximetry during automatic implantable cardioverter-defibrillator placement

Mixed venous oxygen saturation (Sv̄0 2) monitoring was used to assess tissue and circulatory recovery following induced ventricular tachycardia or fibrillation in 17 patients undergoing surgery for automatic implantable cardioverter-defibrillator (AICD) placement. Return of systemic arterial pressur...

Full description

Saved in:
Bibliographic Details
Published inJournal of cardiothoracic anesthesia Vol. 4; no. 4; pp. 453 - 457
Main Authors Van Riper, Daniel F., Horrow, Jan Charles, Kutalek, Stephen P., McCormick, Daniel, Goldman, Scott M.
Format Journal Article
LanguageEnglish
Published Orlando, FL Elsevier Inc 01.08.1990
Grune & Stratton
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Mixed venous oxygen saturation (Sv̄0 2) monitoring was used to assess tissue and circulatory recovery following induced ventricular tachycardia or fibrillation in 17 patients undergoing surgery for automatic implantable cardioverter-defibrillator (AICD) placement. Return of systemic arterial pressure conventionally determines adequate recovery. The duration of circulatory arrest during defibrillator threshold (DFT) testing, measured from the moment of absent phasic pressure at the radial artery until its return, was 18 ± 18 seconds (mean ± SD, n = 118 episodes). The absolute decrease in Sv̄0 2 from baseline to nadir for these 118 episodes was 14% ± 6% absolute, and correlated well with the duration of circulatory arrest ( r = 0.757, P = 0.0001). The time from onset of phasic arterial blood pressure to the nadir of Sv̄0 2, available for 46 episodes, was 28 ± 14 seconds, and did not correlate with the duration of arrest. The time from onset of phasic pressure to the return of Sv̄O 2 to within 1 % (absolute) of baseline saturation, available for 84 episodes, was 52 ± 32 seconds and, in the aggregate, correlated poorly ( r = 0.401) with duration of arrest. Simultaneous recording of arterial pressure and Sv̄0 2 (n = 41) showed that arterial recovery (6 ± 3 seconds) occurred long before Sv̄0 2 recovery (48 ± 16 seconds, P = 0.0001). The authors interpret these data as showing that mixed venous oximetry, compared to arterial blood pressure, provides a more sensitive indicator of tissue recovery following periods of circulatory arrest during DFT testing of AICDs.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0888-6296
DOI:10.1016/0888-6296(90)90290-V