Influence of the climatic conditions on the hygrothermal performance of autoclaved aerated concrete masonry walls
The energy performance of buildings has undergone major developments over the last few years. Due to increasingly demanding regulations, new technologies and constructive solutions have been sought to make buildings more energy efficient. Autoclaved aerated concrete (AAC) is a sustainable building m...
Saved in:
Published in | Journal of Building Engineering Vol. 33; p. 101578 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | English |
Published |
Elsevier Ltd
01.01.2021
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | The energy performance of buildings has undergone major developments over the last few years. Due to increasingly demanding regulations, new technologies and constructive solutions have been sought to make buildings more energy efficient. Autoclaved aerated concrete (AAC) is a sustainable building material that provides a suitable solution to this problem. However, the hygrothermal behavior of AAC masonry walls is the subject of little discussion throughout the scientific community. The paper focuses on identifying the influence of climatic conditions, as well as the effect of surface layers or insulation systems on the hygrothermal performance of exterior walls made of AAC. For the purpose of this study, several constructive solutions were analyzed in different climatic settings, namely Munich, Germany; Stockholm, Sweden; and San Francisco, U. S. A. The effects of applying different types of render/plaster layers or external thermal insulation system on AAC walls was also determined using hygrothermal software. In addition, the damage potential of frost and rainwater were assessed to better comprehend how these walls behave. The results showed that the overall performance of AAC wall systems and frost damage potential was found to be greatly influenced by the hygric properties of the exterior render. Additionally, it was shown that calculating the thermal transmittance in steady-state conditions can lead to gross underestimations compared to transient models. The results indicate that the EPS and XPS insulated walls were susceptible to moisture increase, due to rainwater leakage, unlike the MW insulated wall, which dried significantly faster.
•WDR has a major effect on the water content of AAC masonry walls.•The severity of frost damage on the AAC block is significantly affected by WDR.•The MW insulated walls dried significantly faster than the EPS and XPS systems.•Steady-state U-values are a gross underestimation compared to transient U-values. |
---|---|
ISSN: | 2352-7102 2352-7102 |
DOI: | 10.1016/j.jobe.2020.101578 |